  • A survey was conducted among 108 US spine surgeons to examine their methods and challenges related to intraoperative assessments of spinal alignment during corrective surgery for spinal deformities.
  • The results showed that most surgeons (84%) use C-arm or spot radiographs for alignment checks, while navigation technology is underutilized despite being available at many surgical centers; common barriers include workflow disruption and costs.
  • A significant number of surgeons (87%) expressed the need for improved technology in assessing spinal alignment, highlighting concerns about interruptive workflows, expenses, and radiation exposure as key areas for development.

Article Abstract

Study Design: Survey.

Objectives: To characterize national practices of and shortcomings surrounding intraoperative assessments of spinal alignment.

Methods: Spine surgeons in the US were surveyed to analyze their experience with assessing spinal alignment intraoperatively.

Results: 108 US spine surgeons from 77 surgical centers with an average of 19.2 8.8 years of surgical experience completed the survey. To assess alignment intraoperatively, 84% (91/108) use C-arm or spot radiographs, 40% (43/108) use full-length radiographs, and 20% utilize the T-bar (22/108). 88% of respondents' surgical centers (93/106) possessed a navigation camera and 63% of respondents (68/108) report using surgical navigation for 40% of their deformity cases on average. Reported deterrents for using current technology to assess alignment were workflow interruption (54%, 58/108), expense (33%, 36/108), and added radiation exposure (26%, 28/108). 87% of respondents (82/94) reported a need for improvement in current capabilities of making intraoperative assessments of spinal alignment.

Conclusions: Corrective surgery for spinal deformity is a complex procedure that requires a high level of expertise to perform safely. The majority of surveyed surgeons primarily rely on radiographs for intraoperative assessments of alignment. Despite the majority of surveyed surgical practices possessing navigation cameras, they are utilized only for a minority of spinal deformity cases. With the majority of surveyed surgeons reporting a need for improvement in technology to assess spinal alignment intraoperatively, 3 of the top design considerations should include workflow interruption, expense, and radiation exposure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8998476PMC
http://dx.doi.org/10.1177/21925682211037273DOI Listing

Publication Analysis

Top Keywords

spinal alignment
12
spine surgeons
12
intraoperative assessments
12
majority surveyed
12
assessments spinal
8
surgical centers
8
assess alignment
8
alignment intraoperatively
8
deformity cases
8
technology assess
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!