A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparison of five serological tests for bovine brucellosis. | LitMetric

Five serological assays: the buffered plate antigen test, the standard tube agglutination test, the complement fixation test, the hemolysis-in-gel test and the indirect enzyme immunoassay were diagnostically evaluated. Test data consisted of results from 1208 cattle in brucellosis-free herds, 1578 cattle in reactor herds of unknown infection status and 174 cattle from which Brucella abortus had been cultured. The complement fixation test had the highest specificity in both nonvaccinated and vaccinated cattle. The indirect enzyme immunoassay, if interpreted at a high threshold, also exhibited a high specificity in both groups of cattle. The hemolysis-in-gel test had a very high specificity when used in nonvaccinated cattle but quite a low specificity among vaccinates. With the exception of the complement fixation test, all tests had high sensitivities if interpreted at the minimum threshold. However, the sensitivities of the standard tube agglutination test and indirect enzyme immunoassay, when interpreted at high thresholds were comparable to that of the complement fixation test. A kappa statistic was used to measure the agreement between the various tests. In general the kappa statistics were quite low, suggesting that the various tests may detect different antibody isotypes. There was however, good agreement between the buffered plate antigen test and standard tube agglutination test (the two agglutination tests evaluated) and between the complement fixation test and the indirect enzyme immunoassay when interpreted at a high threshold. With the exception of the buffered plate antigen test, all tests were evaluated as confirmatory tests by estimating their specificity and sensitivity on screening-test positive samples.(ABSTRACT TRUNCATED AT 250 WORDS)

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1255253PMC

Publication Analysis

Top Keywords

complement fixation
20
fixation test
20
indirect enzyme
16
enzyme immunoassay
16
test
14
buffered plate
12
plate antigen
12
antigen test
12
standard tube
12
tube agglutination
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!