Purpose: The purpose of this study was to evaluate the accuracy of a lung stereotactic body radiotherapy (SBRT) treatment plan with the target of a newly predicted internal target volume (ITV) and the feasibility of its clinical application. ITV was automatically generated by our in-house deep learning model according to the cone-beam CT (CBCT) image database.

Method: A retrospective study of 45 patients who underwent SBRT was involved, and Mask R-CNN based algorithm model helped to predict the internal target volume (ITV) using the CBCT image database. The geometric accuracy of ITV was verified by the Dice Similarity Coefficient (DSC), 3D Motion Range (R), Relative Volume Index (RVI), and Hausdorff Distance (HD). The PTV was generated by ITV, which was registered and then projected on free-breath CT (FBCT) images. The PTV was margined from the GTV on FBCT images gross tumor volume on free-breath CT (GTV). Treatment plans with the target of Predict planning target volume on CBCT images (PTV) and planning target volume on free-breath CT (PTV) were respectively re-established, and the dosimetric parameters included the ratio of the volume of patients receiving at least the prescribed dose to the volume of PTV (R), the ratio of the volume of patients receiving at least 50% of the prescribed dose to the volume of PTV in the Radiation Therapy Oncology Group (RTOG) 0813 Trial (R), Gradient Index (GI), and the maximum dose 2 cm from the PTV (D), which were evaluated Plan, plan which based on PTV (Plan), and plan which based on PTV (Plan).

Result: The geometric results showed that there existed a good correlation between ITV and ITV on the 4-dimensional CT [ITV; DSC= 0.83 ±0.18]. However, the average volume of ITV was 10% less than that of ITV ( = 0.333). No significant difference in dose coverage was found in V for the ITV with 99.98 ± 0.04% in the ITV vs. 97.56 ± 4.71% in the ITV ( = 0.162). Dosimetry parameters of PTV, including R, R, GI and D showed no statistically significant difference between each plan ( > 0.05).

Conclusion: Dosimetric parameters of Plan are clinically comparable to those of the original Plan This study confirmed that the treatment plan based on ITV produced by our model could automatically meet clinical requirements. Thus, for patients undergoing lung SBRT, the model has great potential for using CBCT images for ITV contouring which can be used in treatment planning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8980420PMC
http://dx.doi.org/10.3389/fpubh.2022.860135DOI Listing

Publication Analysis

Top Keywords

target volume
16
itv
15
volume itv
12
plan based
12
volume
11
ptv
10
plan
9
lung stereotactic
8
stereotactic body
8
body radiotherapy
8

Similar Publications

This study presents a patient with a PET-CT detected residual lacrimal sac tumor who was treated with intensity modulated proton therapy (IMPT) and concurrent chemotherapy. The patient a 49-year-old male diagnosed with squamous cell carcinoma of the left lacrimal sac had under-went endoscopic surgery. Postoperative PET-CT implied tumor residual in the left lacrimal sac.

View Article and Find Full Text PDF

The role of the hippocampus in working memory and word reading: Novel neural correlates of reading among youth living in the context of economic disadvantage.

Dev Cogn Neurosci

December 2024

Child Mind Institute, New York, NY, USA; Department of Psychiatry and Behavioral Health, The Ohio State University, Columbus, OH, USA. Electronic address:

A left-lateralized cortical reading circuit underlies successful reading and fails to engage in individuals with reading problems. Studies identifying this circuit included youth from economically advantaged backgrounds and focused on cortical, not subcortical, structures. However, among youth with low scores on reading tests who are living in the context of economic disadvantage, this brain network is actively engaged during reading, despite persistent reading problems.

View Article and Find Full Text PDF

Purpose: Total marrow (lymph-node) irradiation (TMI/TMLI) is a radiotherapy technique irradiating the whole body of a patient. The limited couch travel range in modern linacs (130-150 cm) forces to split the TMI/TMLI delivery into two plans with opposite orientation. A dedicated field junction is necessary to achieve satisfactory target coverage in the overlapping region of the two plans.

View Article and Find Full Text PDF

Background: Delirium is a common issue in critical care, yet its prevention and management strategies are often inconsistent. Understanding the factors that lead to the omission or delay in delirium-related care by critical care nurses is essential for enhancing patient outcomes.

Objectives: This study aimed to identify the specific delirium-related prevention and management strategies that are frequently missed or delayed by critical care nurses.

View Article and Find Full Text PDF

Aircraft anti-icers and pavement deicers improve the safety of airport operations during winter precipitation events. Runoff containing these products can contribute elevated biochemical oxygen demand (BOD) to receiving streams. We monitored runoff from Milwaukee Mitchell International Airport at one upstream site, three outfall sites, and one downstream site from 2005 to 2022 for BOD, chemical oxygen demand (COD), and freezing point depressants used in deicing and anti-icing fluids to determine the primary sources of BOD and COD in the receiving stream.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!