Background A midshaft clavicle fracture is a prevalent form of injury of the upper extremity that affects one's quality of life. Several treatment modalities facilitate fixation of the displaced midshaft clavicle to decrease nonunion and malunion of the clavicle fracture. Still, numerous factors influence choosing an optimal surgical intervention. Thus, this study investigates the functional outcome of two standard fixation techniques, titanium elastic nails (TENs) and locking plates, as a prospective comparative study for surgical management of displaced midshaft clavicle fractures. Methods We performed closed/open reduction and internal fixation in 62 patients (40 male and 22 female) with TENs and locking plates, respectively, which were followed up at regular intervals following the surgery (at two, six, 12, 24, and 48 weeks). The surgical outcome was assessed both from functional and radiological standpoints. The influence of surgical fixation on functional outcome was evaluated based on the Constant-Murley score and the fracture recuperation based on union times. Results When compared to plate fixation, TENs had lesser union times. Still, there was no statistical difference in union time between the two groups. The functional assessment graded by Constant-Murley score had a similar distribution of scores between the two groups.With a follow-up of twelve months, the Constant-Murley scores between the groups were not statistically different. While the average score for plate fixation was slightly higher than that of TENs, the nonunion rate was found to be similar in both groups. Conclusion Surgical interventions using both TENs and plate fixation are suitable for managing clavicle midshaft fractures as they have a similar functional outcome. However, considering early recovery with minimal surgical complications, TENs can be a preferred treatment choice for managing displaced midshaft clavicle fractures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8977932PMC
http://dx.doi.org/10.7759/cureus.22862DOI Listing

Publication Analysis

Top Keywords

midshaft clavicle
16
displaced midshaft
12
functional outcome
12
plate fixation
12
comparative study
8
clavicle midshaft
8
clavicle fracture
8
tens locking
8
locking plates
8
clavicle fractures
8

Similar Publications

Background: The incidence rate of subsequent refracture after removal of the implant in mid-shaft clavicle fracture patients is relatively high. This can lead to additional medical costs and cause doctor-patient dispute. This study tries to introduce a new method to predict the refracture risk of the clavicle after hardware removal.

View Article and Find Full Text PDF
Article Synopsis
  • Clavicle fractures are common in emergency departments, while acromioclavicular (AC) joint injuries are rare and even more so when combined with clavicle fractures.
  • A 29-year-old male patient experienced both an AC joint dislocation and a midshaft clavicle fracture, leading to surgical treatment that resulted in excellent recovery and range of motion after one year.
  • The case highlights the rarity of this combination of injuries and stresses the importance of timely diagnosis and investigation to achieve favorable functional outcomes, although there's still no agreement on the best treatment approach.
View Article and Find Full Text PDF

In this report, we present a case of a triple clavicle injury, acromioclavicular joint (ACJ) dislocation, a middle third clavicle fracture, and a sternoclavicular joint (SCJ) subluxation, and describe its successful surgical treatment. A 49-year-old female patient sustained a 3 m fall, resulting in direct trauma to her left shoulder. Initial radiographs and computed tomography (CT) scans revealed a displaced middle third clavicle fracture, a high-grade ACJ dislocation, and a posterior SCJ subluxation.

View Article and Find Full Text PDF

Introduction: Clavicle fractures are routinely encountered in orthopedic clinical practice and have often been the subject of debate when it comes to optimal treatment. Clavicle fracture surgery has come a long way with excellent pre-contoured superior locking plates available for fixation. This study aimed to evaluate a cohort of patients operated for displaced mid-shaft clavicle fractures by open reduction and internal fixation using superior clavicle locking plates.

View Article and Find Full Text PDF

Purpose: Although open reduction and internal fixation (ORIF) is the gold standard treatment for displaced midshaft clavicle fractures, recent studies have advocated for nonoperative management, citing high rates of reoperation associated with operative intervention. However, no studies have compared nonoperative management to ORIF with dual-plate fixation, which may be associated with lower rates of reoperation compared to single-plate fixation. The purpose of this study was to compare the complications and patient-reported outcomes of dual mini-fragment plate fixation to nonoperative management for displaced midshaft clavicle fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!