Background: Current clinical screening tools assessing risky movements during cutting maneuvers do not adequately address sagittal plane foot and ankle evaluations. The Cutting Alignment Scoring Tool (CAST) is reliable in evaluating frontal plane trunk and lower extremity alignment during a 45-degree side-step cut. The Expanded Cutting Alignment Scoring Tool (E-CAST) includes two new sagittal plane variables, knee flexion and ankle plantarflexion angle.

Hypothesis/purpose: To assess the inter-and intra-rater reliability of the E-CAST to evaluate trunk and lower extremity alignment during a 45-degree side-step cut.

Study Design: Repeated Measures.

Methods: Participants included 25 healthy females (13.8 ± 1.4 years) regularly participating in cutting or pivoting sports. Participants were recorded performing a side-step cut in frontal and sagittal planes. One trial was randomly selected for analysis. Two physical therapists independently scored each video using the E-CAST on two separate occasions, with randomization and a two-week wash-out between rounds. Observed movement variables were awarded a score of "1", with higher scores representing poorer technique. Intraclass correlation coefficients (ICC) and 95% confident intervals (95% CI) were calculated for the total score, and a kappa coefficient (k) was calculated for each variable.

Results: The cumulative intra-rater reliability was good (ICC=0.78, 95% CI 0.59-0.96) and the cumulative inter-rater reliability was moderate (ICC=0.71, 95% CI 0.50-0.91). Intra-rater kappa coefficients ranged from moderate to excellent for all variables (k= 0.50-0.84) and inter-rater kappa coefficients ranged from slight to excellent for all variables (k=0.20-0.90).

Conclusion: The addition of two sagittal plane variables resulted in lower inter-rater ICC compared to the CAST (ICC= 0.81, 95% CI 0.64-0.91). The E-CAST is a reliable tool to evaluate trunk and LE alignment during a 45-degree side-step cut, with good intra-rater and moderate inter-rater reliability.

Level Of Evidence: Level 2, Diagnosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8975584PMC
http://dx.doi.org/10.26603/001c.33045DOI Listing

Publication Analysis

Top Keywords

alignment 45-degree
16
45-degree side-step
16
side-step cut
16
cutting alignment
12
alignment scoring
12
scoring tool
12
sagittal plane
12
expanded cutting
8
tool e-cast
8
trunk lower
8

Similar Publications

Purpose: This study aims to investigate the influence of the build angle on the surface characteristics, accuracy, and dimensional stability of digital light processing (DLP) printed resin bases.

Material And Methods: Rectangular and complete denture base samples were fabricated at 0, 45, and 90-degree angles (n = 5 for rectangular samples; n = 10 for maxillary and mandibular denture base samples) using a DLP printer. Surface morphology and roughness were assessed using a profilometer, followed by measuring hydrophilicity with a contact angle meter.

View Article and Find Full Text PDF

Background: The Expanded Cutting Alignment Scoring Tool (E-CAST) has been previously shown to be reliable when assessing lower extremity alignment during a 45-degree sidestep cut, however, the validity of this tool remains unknown. The purpose of this study was to assess the concurrent validity of the E-CAST by comparing visually identified movement errors from two-dimensional (2D) video with three-dimensional (3D) biomechanical variables collected using motion capture.

Study Design: Cross Sectional.

View Article and Find Full Text PDF

Background And Purpose: The Expanded Cutting Alignment Scoring Tool (E-CAST) is a two-dimensional qualitative scoring system that has demonstrated moderate inter-rater and good intra-rater reliability for the assessment of trunk and lower extremity alignment during a 45-degree sidestep cut. The primary purpose of this study was to examine the reliability of the quantitative version of the E-CAST among physical therapists and to compare the reliability of the quantitative E-CAST to the original qualitative E-CAST. The hypothesis was that the quantitative version of the E-CAST would demonstrate greater inter-rater and intra-rater reliability compared to the qualitative E-CAST.

View Article and Find Full Text PDF

A survey of patient contact shielding in dental teaching hospitals in the UK.

J Radiol Prot

March 2023

Department of Dental and Maxillofacial Radiology, University Dental Hospital, Cardiff, United Kingdom.

A high volume of dental imaging is carried out each year. In the UK, guidance on the use of patient contact shielding for these investigations is published by the British Institute of Radiology (BIR) and in a document jointly produced by the Faculty of General Dental Practice and Public Health England (FGDP/PHE). Both these sources of guidance have been updated recently and patient contact shielding is no longer recommended for most imaging settings in dental radiology.

View Article and Find Full Text PDF

Background: Current clinical screening tools assessing risky movements during cutting maneuvers do not adequately address sagittal plane foot and ankle evaluations. The Cutting Alignment Scoring Tool (CAST) is reliable in evaluating frontal plane trunk and lower extremity alignment during a 45-degree side-step cut. The Expanded Cutting Alignment Scoring Tool (E-CAST) includes two new sagittal plane variables, knee flexion and ankle plantarflexion angle.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!