A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fetal Vascular Ectasia Can be an Artifact of Placental Fixation. | LitMetric

Fetal Vascular Ectasia Can be an Artifact of Placental Fixation.

Pediatr Dev Pathol

Department of Pathology and Laboratory Medicine, 6923University of Rochester Medical Center, Rochester, NY, USA.

Published: July 2022

Background: Placentas from outlying hospitals are formalin-fixed en route to our laboratory. We identified that chorionic, stem villus, and umbilical vessels in these fixed placentas are ectatic with greater frequency than in our in-house fresh placentas.

Methods: We searched our LIS for third trimester placentas using keywords "ectasia" or "ectatic" over a 12-month period. We fixed incoming in-house placentas over a 2-week period for 24-72 hours and tabulated the presence or absence of vascular ectasia as defined by Parast et al, 2008.

Results: The LIS search identified 61% of placental cases from outlying hospitals that had ectatic vessels vs 3% of in-house placentas ( < .001). Of 38 placentas fixed in a 2-week period, 45% had ectatic chorionic or stem villus vessels and 21% had umbilical vessel ectasia. In comparison, in the 2 subsequent weeks, 3.8% ( < .001) of fresh placentas had vascular ectasia.

Conclusion: These data suggest that large fetal vessels in the placenta become engorged with blood at delivery and, if fixed soon after delivery, remain ectatic and congested when processed for pathology. The identification of artifactual ectasia is important because fetal vessel ectasia can suggest the presence of fetal vascular malperfusion (FVM) if diagnostic signs of FVM are present.

Download full-text PDF

Source
http://dx.doi.org/10.1177/10935266221083776DOI Listing

Publication Analysis

Top Keywords

fetal vascular
8
vascular ectasia
8
outlying hospitals
8
chorionic stem
8
stem villus
8
in-house placentas
8
2-week period
8
vessel ectasia
8
placentas
7
ectasia
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!