Purpose: To assess the biomechanical deterioration arising from keratoconus progression .

Methods: The preoperative examinations of 32 progressive KC cases that were submitted to corneal cross-linking were evaluated. The examinations included the corneal tomography using the Pentacam HR and biomechanical parameters assessed by the Corvis ST (Oculus, Wetzlar, Germany). The results were recorded at two time points, the latter of which was at the last visit before the CXL procedure. Keratoconus progression was characterised by a significant change in the ABCD system.

Results: At the last follow-up visit (41.4 ± 40.9 months) all morphological parameters of the ABCD grading system showed significant deterioration ( < 0.001). The comparative analyses revealed a significant reduction in corneal stiffness expressed by a significant reduction in the stress-strain index (SSI: -0.10 ± 0.06,  < 0.001), the Stiffness parameter A1 (SP-A1: -6.1 ± 12.0 mmHg/mm,  = 0.011), by a significant increase in the integrated Inverse Radius (IIR: 0.95 ± 1.04 mm-1,  < 0.001) and in the deflection amplitude (DA) ratio (0.23 ± 0.58,  = 0.034). A barely significant increase in the DA also pointed towards corneal stiffness reduction. (0.04 ± 0.13 mm,  = 0.056). The SSI and the IIR were the indices with the smallest overlaps between the two examinations.

Conclusions: It has been demonstrated that corneal biomechanical deterioration occurs with keratoconus progression. The larger changes observed in the SSI and the IIR when compared to the remaining biomechanical parameters suggests that these parameters could be suitable to assess the corneal stiffness reduction in keratoconus natural progression.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02713683.2022.2058020DOI Listing

Publication Analysis

Top Keywords

keratoconus progression
12
vivo biomechanical
4
biomechanical changes
4
changes associated
4
associated keratoconus
4
progression purpose
4
purpose assess
4
assess biomechanical
4
biomechanical deterioration
4
deterioration arising
4

Similar Publications

Keratoconus is a progressive corneal disorder that can lead to irreversible visual impairment if not detected early. Despite its high prevalence, early diagnosis is often delayed, especially in low-to-middle-income countries due to limited awareness and restricted access to advanced diagnostic tools such as corneal topography, tomography, optical coherence tomography, and corneal biomechanical assessments. These technologies are essential for identifying early-stage keratoconus, yet their high cost limits accessibility in resource-limited settings.

View Article and Find Full Text PDF

Repeatability of Pentacam HR in Keratoconus According to Two Different Scan Protocols: 25-3D Scan and 50-Cornea Fine.

J Clin Med

January 2025

Eye Clinic, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, 25121 Brescia, Italy.

This study aims to evaluate the repeatability of the Pentacam HR, comparing two different measurement modes (50-cornea fine and 25-3D scan) in patients affected by keratoconus. Multicenter retrospective study, conducted at Eye Clinic of the ASST-Spedali Civili-University of Brescia, Italy, and St. Paul's Eye Unit, Royal Liverpool University Hospital, United Kingdom.

View Article and Find Full Text PDF

Purpose: Although mechanical injury to the cornea (e.g. chronic eye rubbing) is a known risk factor for keratoconus progression, how it contributes to loss of corneal integrity is not known.

View Article and Find Full Text PDF

Background And Objective: This study determined whether practitioners specializing in keratoconus (KC) adhere to published guidelines for disease management and to what extent comorbid conditions of dry eye, contact lens tolerance, and psychological consequences of KC are formally assessed as part of long-term management.

Materials And Methods: This cross-sectional study used an IRB-approved, Internet-based, REDCap platform. Descriptive statistics are presented.

View Article and Find Full Text PDF

Contact lenses have become integral tools in the realm of ocular therapeutics, extending beyond their primary function of refractive correction to encompass a diverse array of therapeutic applications. This review explores the evolving role of contact lenses in managing various ocular conditions, highlighting their efficacy in enhancing patient outcomes. Initially developed to correct refractive errors, contact lenses now serve as effective vehicles for delivering medications directly to the ocular surface, offering targeted treatment for conditions such as dry eye syndrome and corneal ulcers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!