Multisite MRI reproducibility of lateral ventricular volume using the NAIMS cooperative pilot dataset.

J Neuroimaging

Buffalo Neuroimaging Analysis Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, New York, USA.

Published: September 2022

Background And Purpose: The North American Imaging in Multiple Sclerosis (NAIMS) multisite project identified interscanner reproducibility issues with T1-based whole brain volume (WBV). Lateral ventricular volume (LVV) acquired on T2-fluid-attenuated inverse recovery (FLAIR) scans has been proposed as a robust proxy measure. Therefore, we sought to determine the relative magnitude of scanner-induced T2-FLAIR-based LVV and T1-based WBV measurement errors in relation to clinically meaningful changes.

Methods: This was a post hoc analysis of the NAIMS pilot dataset in which a relapsing-remitting MS patient with no intrastudy clinical or radiological activity was imaged twice on seven different Siemens scanners across the United States. LVV was determined using the automated NeuroSTREAM technique on T2-FLAIR and WBV was determined with SIENAX on high-resolution T1-MPRAGE. Average LVV and WBV were measured, and absolute intrascanner and interscanner coefficients of variation (CoVs) were calculated. The variabilities were compared to previously established annual pathological and clinically meaningful cutoffs of 0.40% for WBV and of 3.51% for LVV.

Results: Mean LVV across all seven scan/rescan pairs was 45.87 ± 1.15 ml. Average LVV intrascanner CoV was 1.42% and interscanner CoV was 1.78%, both smaller than the reported annualized clinically meaningful cutoff of 3.51%. In contrast, intra- and interscanner CoVs for WBV (0.99% and 1.15%) were both higher than the established cutoff of 0.40%. Individually, 1/7 intrasite and 2/7 intersite pair-wise LVV comparisons were above the 3.51% cutoff, whereas 4/7 intrasite and 7/7 intersite WBV comparisons were above the 0.40% cutoff.

Conclusion: Fully automated LVV segmentation has higher absolute variability than WBV, but much lower relative variability compared to clinically relevant changes, and may therefore be a meaningful proxy outcome measure of neurodegeneration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9835837PMC
http://dx.doi.org/10.1111/jon.12998DOI Listing

Publication Analysis

Top Keywords

clinically meaningful
12
lateral ventricular
8
ventricular volume
8
pilot dataset
8
wbv
8
lvv
8
average lvv
8
multisite mri
4
mri reproducibility
4
reproducibility lateral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!