Application of an accelerometer in adjusting parameters and detecting characteristics in the pacemaker rate response.

Physiol Meas

Department of Electronic and Information Engineering, Shantou University College of Engineering, No. 243 Da Xue Road, 515063 Shantou City, Guangdong Province, People's Republic of China.

Published: April 2022

To study the application of an accelerometer in adjusting the parameters, setting the sensor indicated rate (SIR) and detecting characteristics in the pacemaker (PM) rate response.Three-axis (GT9X Link-type) accelerometers were positioned on the waist and chest in 33 participants implanted with rate responsive PMs while wearing an ambulatory ECG recorder (Holter). During the walking test, by collecting vertical axis (Axis-1) activity intensity counts, Axis-1' metabolic equivalent of energy (MET) and its expected heart rate (HR) were calculated by the relevant equations, and on the basis of the HRas the target heart rate, the SIR was set by programming the rate response slope parameter. During the following daily walking activity, the physical activity parameters and Holter ECG was recorded continuously. After the end of the whole test the analysis on these data recorded was performed retrospectively.After completing the SIR setting, in 24 participants with complete ventricular pacing the comparison between HR(92.5 ± 7.8 BPM) and the HR(94.0 ± 10.5 BPM) showed no statistical difference (ΔHR: 1.25 ± 6.69 BPM,: 0.568) during the last one walking test, and there was also no significant difference (ΔHR: 2.8 ± 7.1 BPM,: 0.398) between the HR(90.7 ± 7.1 BPM) and HR(93.4 ± 10.3 BPM) during daily walking activity. In addition, in the data of 108 time intervals selected during the daily walking activities in the abovementioned 24 participants, METand HRcorrelation analysis showed good correlation and the regression equation was HR = 12.4 × MET±43.1 (P<0.0001).An accelerometer can play an important role in adjusting parameters, setting the SIR and detecting characteristics in the PM rate response.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6579/ac5467DOI Listing

Publication Analysis

Top Keywords

daily walking
12
application accelerometer
8
accelerometer adjusting
8
adjusting parameters
8
detecting characteristics
8
characteristics pacemaker
8
pacemaker rate
8
rate response
8
rate sir
8
walking test
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!