Download full-text PDF

Source
http://dx.doi.org/10.1007/s00256-022-04052-2DOI Listing

Publication Analysis

Top Keywords

correction measuring
4
measuring critical
4
critical shoulder
4
shoulder angle
4
angle radiographs
4
radiographs accurate
4
accurate repeatable
4
repeatable deep
4
deep learning
4
learning model
4

Similar Publications

Count-rate management in I SPECT/CT calibration.

EJNMMI Phys

January 2025

Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.

Background: System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.

View Article and Find Full Text PDF

Comparing the Palmar Radiocarpal Artery Vascularized Bone Graft with Alternatives for Unstable Scaphoid Nonunions: A Retrospective Analysis.

J Hand Surg Am

January 2025

The Ottawa Hospital, Ottawa, ON, Canada; Division of Orthopaedic Surgery, The Ottawa Hospital Ottawa, ON, Canada; Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada. Electronic address:

Purpose: We compared the radiographic union and magnitude of humpback deformity correction when using different vascularized bone grafts (VBGs) and nonvascularized bone grafts (NVBGs) in the treatment of unstable scaphoid nonunions (USNUs).

Methods: This was a retrospective radiographic review of 93 patients with an USNU treated between 2013 and 2022 at a single center by a single surgeon. Inclusion criteria included skeletally mature patients with radiographic evidence of an USNU resulting from failure of either nonsurgical or operative treatment.

View Article and Find Full Text PDF

Study Objective: The osmol gap can help detect and manage those with toxic alcohol exposure, and it is altered by all alcohols including ethanol. The optimal correction for ethanol that would allow accurate detection of an alternative alcohol is unclear.

Methods: We conducted a prospective cohort study to assess baseline variations in osmol gap, and then to assess the validity of 2 commonly used coefficients (correction factors) for ethanol.

View Article and Find Full Text PDF

Measurement and Assessment of Head-to-Helmet Contact Forces.

Ann Biomed Eng

January 2025

Department of Mechanical and Industrial Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA.

Purpose: To evaluate the population variation in head-to-helmet contact forces in helmet users.

Methods: Four different size Kevlar composite helmets were instrumented with contact pressure sensors and chinstrap tension meters. A total number of 89 volunteers (25 female and 64 male volunteers) participated in the study.

View Article and Find Full Text PDF

Potential therapeutic effect of dimethyl fumarate on Treg/Th17 cell imbalance in biliary atresia.

Clin Immunol

January 2025

Department of Pediatric Surgery, Children's Hospital of Fudan University, Shanghai Key Laboratory of Birth Defect, and Key Laboratory of Neonatal Disease, Ministry of Health, Shanghai 201102, China. Electronic address:

The imbalance between Tregs and proinflammatory Th17 cells in children with biliary atresia (BA) causes immune damage to cholangiocytes. Dimethyl fumarate (DMF), an immunomodulatory drug, regulates the Treg/Th17 balance in diseases like multiple sclerosis (MS). This study explores DMF's effect on Treg/Th17 balance in BA and its potential mechanism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?