AI Article Synopsis

Article Abstract

Objectives: To evaluate the diagnostic value of deep learning model (DLM) reconstructed dual-energy CT (DECT) low-keV virtual monoenergetic imaging (VMI) for assessing hypoenhancing hepatic metastases.

Methods: This retrospective study included 131 patients who underwent contrast-enhanced DECT (80-kVp and 150-kVp with a tin filter) in the portal venous phase for hepatic metastasis surveillance. Linearly blended images simulating 100-kVp images (100-kVp), standard 40-keV VMI images (40-keV VMI), and post-processed 40-keV VMI using a vendor-agnostic DLM (i.e., DLM 40-keV VMI) were reconstructed. Lesion conspicuity and diagnostic acceptability were assessed by three independent reviewers and compared using the Wilcoxon signed-rank test. The contrast-to-noise ratios (CNRs) were also measured placing ROIs in metastatic lesions and liver parenchyma. The detection performance of hepatic metastases was assessed by using a jackknife alternative free-response ROC method. The consensus by two independent radiologists was used as the reference standard.

Results: DLM 40-keV VMI, compared to 40-keV VMI and 100-kVp, showed a higher lesion-to-liver CNR (8.25 ± 3.23 vs. 6.05 ± 2.38 vs. 5.99 ± 2.00), better lesion conspicuity (4.3 (4.0-4.7) vs. 3.7 (3.7-4.0) vs. 3.7 (3.3-4.0)), and better diagnostic acceptability (4.3 (4.0-4.3) vs. 3.0 (2.7-3.3) vs. 4.0 (4.0-4.3)) (p < 0.001 for all). For lesion detection (246 hepatic metastases in 68 patients), the figure of merit was significantly higher with DLM 40-keV VMI than with 40-keV VMI (0.852 vs. 0.822, p = 0.012), whereas no significant difference existed between DLM 40-keV VMI and 100-kVp (0.852 vs. 0.842, p = 0.31).

Conclusions: DLM 40-keV VMI provided better image quality and comparable diagnostic performance for detecting hypoenhancing hepatic metastases compared to linearly blended images.

Key Points: • DLM 40-keV VMI provides a superior image quality compared with 40-keV or 100-kVp for assessing hypoenhancing hepatic metastasis. • DLM 40-keV VMI has the highest CNR and lesion conspicuity score for hypoenhancing hepatic metastasis due to noise reduction and structural preservation. • DLM 40-keV VMI provides higher lesion detectability than standard 40-keV VMI (p = 0.012).

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-022-08728-0DOI Listing

Publication Analysis

Top Keywords

40-kev vmi
56
dlm 40-kev
32
hypoenhancing hepatic
20
40-kev
16
hepatic metastasis
16
vmi
15
lesion conspicuity
12
hepatic metastases
12
• dlm
12
dlm
10

Similar Publications

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Objective: To investigate the potential role of dual-energy spectral computer tomography (CT) quantitative parameters in the definition of bladder cancer (BCa) pathological grading.

Methods: This retrospective study evaluated the use of spectral CT imaging features for BCa. From 2021 to 2023, 63 patients with histologically-confirmed BCa diagnosis were examined at our Institution.

View Article and Find Full Text PDF

This study aimed to investigate the potential benefit of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) angiography in visualization of abdominal arteries in comparison to standard-reconstruction (SR) images of virtual monoenergetic images (VMI) at low kiloelectron volt (keV). We prospectively included 47 and 47 participants to undergo contrast-enhanced abdominal CT scans within UHR mode on a PCD-CT system using full-dose (FD) and low-dose (LD) protocols, respectively. The data were reconstructed into six series of images: FD_UHR_Br48, FD_UHR_Bv56, FD_UHR_Bv60, FD_SR_Bv40, LD_UHR_Bv48, and LD_SR_Bv40.

View Article and Find Full Text PDF
Article Synopsis
  • Coronary computed tomography angiography (CCTA) is a non-invasive method for diagnosing coronary artery issues, utilizing intravenous contrast agents for better imaging, specifically evaluating the potential use of gadolinium-based contrast agents (GBCA) instead of traditional iodinated contrast.
  • A dynamic phantom model was employed to test different GBCA injection protocols at varying doses, and virtual monoenergetic image reconstructions were made to analyze the performance of GBCA in CCTA.
  • The study found that while higher GBCA doses improved image quality, current dual-source photon-counting-detector CT systems can't effectively use GBCA at approved doses, suggesting a need for future technological advancements to optimize its application, especially for patients with iodine allergies.
View Article and Find Full Text PDF
Article Synopsis
  • This study aimed to assess the effectiveness of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) in identifying severe lung injuries and atelectasis in patients with multiple traumas.
  • A total of 20 patients were examined using contrast-enhanced PCD-CT, with images created at different energy levels (40 to 120 keV) to analyze the contrast-to-noise ratio between injured and collapsed lung areas.
  • Results showed that lower energy levels (specifically around 40-50 keV) provided the best contrast and clarity for differentiating between severe lung injury and atelectasis, while higher energy levels like 60-70 keV offered better noise perception
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!