A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the SMARTCHEK Genesystem RT-qPCR assay for the detection of SARS-CoV-2 in clinical samples. | LitMetric

AI Article Synopsis

  • The COVID-19 pandemic continues to be a significant public health issue, with RT-qPCR being the main method for detecting the SARS-CoV-2 virus.
  • A study evaluated the RT-qPCR SMARTCHEK platform for SARS-CoV-2 detection using samples from 360 suspected COVID-19 cases in Peru, comparing it to traditional RT-qPCR.
  • Results showed that the SMARTCHEK platform has high sensitivity (98.1%) and specificity (98.8%), making it a reliable and quick alternative for diagnosing COVID-19, particularly in low-resource environments.

Article Abstract

Background: The COVID-19 pandemic remains the main public health problem, due to the quick and easy dissemination of the causal agent, SARS-CoV-2 virus, around the world. Since the beginning of the pandemic, an opportune laboratory diagnosis has been critical to respond this emergency, and RT-qPCR has been used as reference molecular tests for detection of SARS-CoV-2.

Methods: In this study, we performed the evaluation of a RT-qPCR SMARTCHEK platform (SMARTCHEK, Genesystem) for SARS-CoV-2 detection based on the amplification of RdRp and N gene markers. The platform was evaluated with nasopharyngeal swab samples corresponding to 360 suspected cases of COVID-19 which were remitted to Instituto Nacional de Salud in Peru. This quick method was compared with conventional RT-qPCR as gold standard.

Results: The RT-qPCR SMARTCHEK showed a 98.1% sensitivity (CI: 93.3-99.8%), a 98.8% specificity (CI: 96.6-99.8%), a 97.2% positive predictive value (CI: 92-99.4%) and a 99.2% negative predictive value (CI: 97.2-99.9%). The assay demonstrated a strong agreement between the RT-qPCR SMARTCHEK and conventional RT-qPCR (kappa value ≥ 0.966).

Conclusion: The RT-qPCR SMARTCHEK is a platform that gives reliable and fast results, with high sensitivity and specificity for the detection of SARS-CoV-2, and it will be considered a suitable alternative to COVID-19 diagnosis in low-resource settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8977556PMC
http://dx.doi.org/10.1186/s12879-022-07319-0DOI Listing

Publication Analysis

Top Keywords

rt-qpcr smartchek
16
smartchek genesystem
8
rt-qpcr
8
detection sars-cov-2
8
smartchek platform
8
conventional rt-qpcr
8
smartchek
5
evaluation smartchek
4
genesystem rt-qpcr
4
rt-qpcr assay
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!