Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The radiological complications including correction loss and hardware failure of short segment posterior pedicle screw fixation in the treatment of unstable thoracolumbar burst fractures remain a main concern. Several procedures aiming to reinforce the anterior column have been introduced to solve these limitations, including transforaminal interbody fusion (TIF). The purposes of this study were to evaluate the radiological complications of short-segment pedicle screw fixation in combination with transforaminal interbody fusion in the treatment of unstable thoracolumbar burst fractures.
Methods: This retrospective case series study enrolled patients with isolated unstable thoracolumbar burst fractures, who were treated by posterior short fixation with TIF between January 2013 and January 2017. Patients were followed up for a minimum of one and half years. For evaluation of correction loss, % loss of anterior vertebral body height (%AVB), vertebral kyphotic angle (VA) and regional kyphotic angle (RA) were collected preoperatively, postoperatively and at the final follow-up. Hardware failure was assessed on radiological images at the last follow-up.
Results: There were 36 patients who met the inclusion criteria with a mean follow-up duration of 53 months. The mean correction loss of %AVB, VA and RA were 10.2%, 2.9 and 5.6, respectively. There were 6 patients (16.7%) with hardware failure at the final follow-up.
Conclusion: Short-segment posterior pedicle screw fixation with TIF using bone chip grafts does not completely prevent hardware failure and progressive kyphosis in the treatment of unstable thoracolumbar burst fractures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8976479 | PMC |
http://dx.doi.org/10.2147/ORR.S356296 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!