Vestibular evoked myogenic potentials (VEMPs) are routinely used to test otolith function, but which specific vestibular afferent neurons and central circuits are activated by auditory frequency VEMP stimuli remains unclear. To examine this question, we analyzed the sensitivity of individual vestibular afferents in adult Sprague-Dawley rats to tone bursts delivered at 9 frequencies (125-4000 Hz) and 3 intensity levels (60, 70, 80 dB SL re: acoustic brainstem response (ABR) threshold). Afferent neuron tone sensitivity was quantified by the cumulative probability of evoking a spike (CPE). Based on a threshold CPE of 0.1, acoustic stimuli in the present study evoked responses in 78.2 % (390/499) of otolith afferent neurons vs. 48.4 % (431/891) of canal afferent neurons. Organ-specific vestibular inputs to the central nervous system in response to tone bursts differ based on intensity and frequency content of the stimulus. At frequencies below 500 Hz, tone bursts primarily activated both otolith afferents, even at the highest intensity tested (80 dB SL re ABR threshold). At 1500 Hz, however, tone bursts activated the canal and otolith afferents at the moderate and high intensities tested (70, 80 dB SL), but activated only otolith afferents at the low intensity tested (60 dB SL). Within an end organ, diversity of sensitivity between individual afferent neurons correlated with spontaneous discharge rate and regularity. Examination of inner ear fluid mechanics in silico suggests that the frequency response and preferential activation of the otolith organs likely arise from inner ear fluid motion trapped near the oval and round windows. These results provide insight into understanding the mechanisms of sound activation of the vestibular system and developing novel discriminative VEMP testing protocols and interpretative guidelines in humans.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9086073PMC
http://dx.doi.org/10.1007/s10162-022-00839-1DOI Listing

Publication Analysis

Top Keywords

tone bursts
20
otolith afferents
16
afferent neurons
16
canal otolith
8
sensitivity individual
8
abr threshold
8
bursts activated
8
activated otolith
8
intensity tested
8
tested 80 db
8

Similar Publications

Effect of induced astigmatism on vestibulo-ocular reflex.

Clin Exp Optom

January 2025

Department of Optometry, School of Paramedical and Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.

Clinical Relevance: The vestibular-ocular reflex stabilises the retinal image and maintains balance during head movement. Astigmatism is one of the common refractive errors that can reduce the quality of visual inputs.

Background: The purpose of this study was to investigate the effect of induced astigmatism on the function of the vestibular-ocular reflex.

View Article and Find Full Text PDF

This study delves into the feasibility of leveraging quasi-static component (QSC) generation during primary Lamb wave propagation to discern subtle alterations in the interfacial properties of a two-layered plate. Unlike the second-harmonic generation of Lamb waves, QSC generation doesn't necessitate precise phase-velocity matching but rather requires an approximate matching of group velocities to ensure the emergence of cumulative growth effects. This unique characteristic empowers the QSC-based nonlinear ultrasonic method to effectively surmount the limitations associated with inherent dispersion and multimode traits of Lamb wave propagation.

View Article and Find Full Text PDF

Intravascular Sympathetic Stimulation to Facilitate Catheter Ablation of Premature Ventricular Complexes.

JAMA Cardiol

December 2024

Section for Cardiac Electrophysiology, Division of Cardiovascular Medicine, Department of Medicine, University of Pennsylvania, Philadelphia.

Importance: Infrequent intraprocedural premature ventricular complexes (PVCs) limit the efficacy of catheter ablation. Intravascular stimulation of sympathetic nerves via vertebral veins (VVs) has been used to activate cardiac sympathetic tone and may promote PVCs.

Objective: To characterize the ability of direct electrical sympathetic stimulation via VVs to induce PVCs at the time of catheter ablation.

View Article and Find Full Text PDF

Objectives: Auditory brainstem response (ABR) is the gold standard to assess hearing loss in pediatric patients. Multiple widely accepted ABR protocols with varying parameters are accepted, difference in standards may lead to misdiagnosis or delay in diagnosis and treatment. This study investigates the quality of ABR testing in pediatric patients in addition to changes in diagnoses and management.

View Article and Find Full Text PDF

Objective:  The objectives of the study were to (i) evaluate the effectiveness of wideband absorbance (WBA) at ambient pressure (WBA), tympanic peak pressure (WBA), and 0 daPa (WBA) to identify conductive hearing loss (CHL) in infants and (ii) compare the sensitivity and specificity of the three WBA tests with that of high-frequency tympanometry (HFT) and transient-evoked otoacoustic emissions (TEOAE).

Method:  A total of 31 ears with hearing thresholds no greater than 20 dB HL (reference group from 20 infants [mean age: 3.1 weeks]) and 47 ears with CHL from 31 infants (mean age: 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!