Magnetic resonance imaging serves as an essential tool for clinical diagnosis, however, suffers from a long acquisition time. Sparse sampling effectively saves this time but images need to be faithfully reconstructed from undersampled data. Among the existing reconstruction methods, the structured low-rank methods have advantages in robustness to the sampling patterns and lower error. However, the structured low-rank methods use the 2D or higher dimension k-space data to build a huge block Hankel matrix, leading to considerable time and memory consumption. To reduce the size of the Hankel matrix, we proposed to separably construct multiple small Hankel matrices from rows and columns of the k-space and then constrain the low-rankness on these small matrices. This separable model can significantly reduce the computational time but ignores the correlation existed in inter- and intra-row or column, resulting in increased reconstruction error. To improve the reconstructed image without obviously increasing the computation, we further introduced the self-consistency of k-space and virtual coil prior. Besides, the proposed separable model can be extended into other imaging scenarios which hold exponential characteristics in the parameter dimension. The in vivo experimental results demonstrated that the proposed method permits the lowest reconstruction error with a fast reconstruction. The proposed approach requires only 4% of the state-of-the-art STDLR-SPIRiT runtime for parallel imaging reconstruction, and achieves the fastest computational speed in parameter imaging reconstruction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TMI.2022.3164472 | DOI Listing |
Z Med Phys
January 2025
Aix-Marseille Univ, CNRS, CRMBM, Marseille, France; APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France; Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Purpose: To develop an improved post-processing pipeline for noise-robust accelerated phase-cycled Cartesian Single (SQ) and Triple Quantum (TQ) sodium (Na) Magnetic Resonance Imaging (MRI) of in vivo human brain at 7 T.
Theory And Methods: Our pipeline aims to tackle the challenges of Na Multi-Quantum Coherences (MQC) MRI including low Signal-to-Noise Ratio (SNR) and time-consuming Radiofrequency (RF) phase-cycling. Our method combines low-rank k-space denoising for SNR enhancement with Dynamic Mode Decomposition (DMD) to robustly separate SQ and TQ signal components.
Quant Imaging Med Surg
January 2025
Henan Key Laboratory of Imaging and Intelligent Processing, Information Engineering University, Zhengzhou, China.
Background: Photon-counting computed tomography (CT) is an advanced imaging technique that enables multi-energy imaging from a single scan. However, the limited photon count assigned to narrow energy bins leads to increased quantum noise in the reconstructed spectral images. To address this issue, leveraging the prior information in the spectral images is essential.
View Article and Find Full Text PDFInf inference
March 2025
Program in Applied Mathematics, Yale University, New Haven, CT 06520, US.
Detecting and recovering a low-rank signal in a noisy data matrix is a fundamental task in data analysis. Typically, this task is addressed by inspecting and manipulating the spectrum of the observed data, e.g.
View Article and Find Full Text PDFJ Chem Theory Comput
January 2025
Key Laboratory of Precision and Intelligent Chemistry, and Department of Chemical Physics, University of Science and Technology of China, Hefei, Anhui 230026, China.
Hybrid functionals that incorporate exact Hartree-Fock exchange (HFX) into density functional theory (DFT) are crucial for accurately predicting the electronic structures of extended systems in condensed-matter physics and materials science. Although the exact exchange contributes only a small fraction of the total energy, HFX calculations in hybrid functionals demand significant computational resources. Here, we introduce dual-grid and mixed-precision techniques, based on two low-rank approximations, adaptively compressed exchange (ACE) and interpolative separable density fitting (ISDF) methods, to significantly improve the computational efficiency of plane-wave hybrid functional calculations in the software package PWDFT (plane wave density functional theory).
View Article and Find Full Text PDFComput Med Imaging Graph
December 2024
Medical Image and Data Analysis (MIDAS.lab), Department of Diagnostic and Interventional Radiology, University of Tuebingen, Tuebingen, Germany.
Cardiac Cine Magnetic Resonance Imaging (MRI) provides an accurate assessment of heart morphology and function in clinical practice. However, MRI requires long acquisition times, with recent deep learning-based methods showing great promise to accelerate imaging and enhance reconstruction quality. Existing networks exhibit some common limitations that constrain further acceleration possibilities, including single-domain learning, reliance on a single regularization term, and equal feature contribution.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!