Background: It is unknown whether the direct oral anticoagulant edoxaban can reduce leaflet thrombosis and the accompanying cerebral thromboembolic risk after transcatheter aortic valve replacement. In addition, the causal relationship of subclinical leaflet thrombosis with cerebral thromboembolism and neurological or neurocognitive dysfunction remains unclear.
Methods: We conducted a multicenter, open-label randomized trial comparing edoxaban with dual antiplatelet therapy (aspirin plus clopidogrel) in patients who had undergone successful transcatheter aortic valve replacement and did not have an indication for anticoagulation. The primary end point was an incidence of leaflet thrombosis on 4-dimensional computed tomography at 6 months. Key secondary end points were the number and volume of new cerebral lesions on brain magnetic resonance imaging and the serial changes of neurological and neurocognitive function between 6 months and immediately after transcatheter aortic valve replacement.
Results: A total of 229 patients were included in the final intention-to-treat population. There was a trend toward a lower incidence of leaflet thrombosis in the edoxaban group compared with the dual antiplatelet therapy group (9.8% versus 18.4%; absolute difference, -8.5% [95% CI, -17.8% to 0.8%]; =0.076). The percentage of patients with new cerebral lesions on brain magnetic resonance imaging (edoxaban versus dual antiplatelet therapy, 25.0% versus 20.2%; difference, 4.8%; 95% CI, -6.4% to 16.0%) and median total new lesion number and volume were not different between the 2 groups. In addition, the percentages of patients with worsening of neurological and neurocognitive function were not different between the groups. The incidence of any or major bleeding events was not different between the 2 groups. We found no significant association between the presence or extent of leaflet thrombosis with new cerebral lesions and a change of neurological or neurocognitive function.
Conclusions: In patients without an indication for long-term anticoagulation after successful transcatheter aortic valve replacement, the incidence of leaflet thrombosis was numerically lower with edoxaban than with dual antiplatelet therapy, but this was not statistically significant. The effects on new cerebral thromboembolism and neurological or neurocognitive function were also not different between the 2 groups. Because the study was underpowered, the results should be considered hypothesis generating, highlighting the need for further research.
Registration: URL: https://www.
Clinicaltrials: gov. Unique identifier: NCT03284827.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCULATIONAHA.122.059512 | DOI Listing |
J Cardiovasc Surg (Torino)
December 2024
Department of Cardiovascular and Thoracic Surgery, Dijon University Hospital, Dijon, France.
Background: In the last years, the Cor-Knot device has been increasingly used in heart valve surgery. Our aim was to investigate the incidence of valvular complications in patients who underwent valvular surgery using the Cor-Knot device in multicentric cohorts at one-year follow-up.
Methods: Three hundred and sixty-eight patient underwent heart valve repair or replacement surgery using automated titanium suture fasteners in four cardiothoracic surgery departments between September 2018 and January 2020.
Catheter Cardiovasc Interv
January 2025
Cardiology Department, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal.
Transcatheter aortic valve replacement (TAVR) is a well-established treatment for severe aortic stenosis, especially in patients over 75 or those at high surgical risk. While these prosthetic valves have a lower thrombogenic profile than mechanical heart valves, leaflet thrombosis in transcatheter aortic valves (TAV) occurs in an estimated 5%-40% of cases. Most TAV thromboses are subclinical and can be detected via cardiac computed tomography (CCT), which reveals hypo-attenuating leaflet thickening and reduced leaflet motion in asymptomatic patients without elevated transprosthetic gradients on echocardiography.
View Article and Find Full Text PDFInt J Cardiol
December 2024
Section of Cardiology, Department of Medicine, Baylor College of Medicine, Houston, TX, USA. Electronic address:
Leaflet thrombosis after transcatheter aortic valve replacement (TAVR) presents a significant challenge, leading to adverse clinical outcomes. Subclinical leaflet thrombosis (SLT) is increasingly recognized, and there is a growing concern about its role in clinical events and hemodynamic valve deterioration. Current recommendations for prophylactic anticoagulation or antiplatelet therapy following TAVR are primarily based on expert consensus rather than definitive evidence from randomized trials, resulting in a variety of antithrombotic strategies in clinical practice.
View Article and Find Full Text PDFCJC Open
December 2024
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Background: The short-term and midterm impact of gender differences on transcatheter aortic valve implantation (TAVI) has been studied. However, the impact on long-term clinical outcomes remains unclear. The objective of the study was to investigate the impact of gender differences after TAVI on long-term clinical outcomes and structural valve deterioration (SVD).
View Article and Find Full Text PDFJ Vasc Access
December 2024
Clinical Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.
The fibroblastic sleeve is a structure potentially enveloping any intravascular device. At ultrasound scan, it typically presents as a thin layer of variably echogenic material covering the catheter surface, which usually tends to remain into the vessel after the catheter removal. However, several case reports have documented its migration toward the heart or pulmonary artery after a central venous catheter removal.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!