A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biofilm accumulation on additive manufactured Ti-6Al-4V alloy surfaces. | LitMetric

Purpose: This study investigated whether additive manufactured (AM) surfaces inhibit accumulation of bacterial biofilm on the surfaces of Ti-6Al-4V alloy dental implants. Bacterial biofilms are thought to cause peri-implant disease, which develops in mucosa surrounding titanium (Ti) and Ti alloy dental implants and can lead to bone loss and implant failure.

Methods: Accumulation of a Streptococcus mutans (ATCC 25175) biofilm on Ti-6Al-4V alloy was compared in relation to fabrication method, ie, AM using electron beam melting (EBM) or laser beam melting (LBM). Conventional lost-wax casting was used as positive control, and Teflon was used as negative control. Biofilm accumulation on the alloys and negative control (each n = 10) was conducted at 37°C under anaerobic conditions. After 4 h, the number of metabolically active S. mutans bacteria adhering to the alloy was determined with a bioluminescence assay.

Results: The quantitative roughness values of the specimens, before exposure to bacteria, ranked EBM > LBM > cast > Teflon.

Conclusion: The amount of biofilm accumulation on the investigated AM metals and cast metal controls did not significantly differ.

Download full-text PDF

Source
http://dx.doi.org/10.2334/josnusd.21-0521DOI Listing

Publication Analysis

Top Keywords

biofilm accumulation
12
ti-6al-4v alloy
12
additive manufactured
8
alloy dental
8
dental implants
8
beam melting
8
negative control
8
biofilm
5
alloy
5
accumulation additive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!