Background: Peritoneal dialysis (PD) is the RRT of choice in 15% of patients with CKD and has multiple advantages over hemodialysis. PD leaks can prompt technique failure and dropout. Use of peritoneal scintigraphy (PS) for diagnosis of PD leaks has declined in favor of more complex and expensive tests. We analyzed the utility of PS for PD leak diagnosis in our center.
Methods: We retrospectively analyzed all PS done in our center from January 2000 until December 2018, inclusive, in all patients on PD with a suspected dialysate leak.
Results: A total of 39 PS procedures were done in 36 patients on PD in the study period. Of those, 81% were male and 11% had CKD due to polycystic kidney disease. During this period, 23 leaks were diagnosed, showing an incidence of 6% (three episodes per patient per year). In all cases with negative PS, other tests did not confirm a peritoneal dialysate leak.
Conclusions: PS is a safe, inexpensive, reproducible, and highly effective diagnostic tool for peritoneal dialysate leaks that allows nephrologists to tailor or stop PD therapy if required. In our opinion, it should be the first-line imaging test to diagnose PD leaks with minimum exposure to radiation, contrast, or other substances that could irritate the peritoneal membrane. We believe PS should be considered as the initial test of choice to diagnose this PD complication as soon as possible, minimizing technique failure and dropout due to leaks.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8809284 | PMC |
http://dx.doi.org/10.34067/KID.0000302020 | DOI Listing |
Endocrine
December 2024
Nuclear Medicine and Molecular Imaging, Institut de Cancérologie Strasbourg Europe (ICANS), University Hospitals of Strasbourg, University of Strasbourg, Strasbourg, France.
Purpose: To evaluate organ-specific response to [Lu]DOTATATE Peptide Receptor Radionuclide Therapy (PRRT) in patients with small intestine neuroendocrine tumor (SiNET) through [Ga]DOTATOC PET/CT, and to analyze tumor uptake and functional volume variations at different metastatic sites in relation to disease progression during clinical follow-up after treatment.
Methods: A retrospective analysis was conducted on 33 metastatic patients. PET/CT were performed pre-treatment (PET0), mid-treatment after two PRRT cycles (PET2), and post-treatment (PET4).
BMC Med Imaging
December 2024
Department of Radiology, The First Affiliated Hospital of Xiamen University, 55 Zhenhai Road, Xiamen, 361000, People's Republic of China.
Purpose: Exploring the computed tomography (CT), magnetic resonance imaging (MRI), and fluorodeoxyglucose positron emission tomography (FDG-PET)/CT Multimodal Imaging Characteristics of Desmoplastic Small Round Cell Tumor (DSRCT) to enhance the diagnostic proficiency of this condition.
Methods: A retrospective analysis was performed on clinical data and multimodal imaging manifestations (CT, MRI, FDG-PET/CT) of eight cases of DSRCT. These findings were systematically compared with pathological results to succinctly summarize imaging features and elucidate their associations with both clinical and pathological characteristics.
Clin Nucl Med
December 2024
From the Department of Nuclear Medicine, Istanbul University, Istanbul Medical Faculty, Istanbul, Turkey.
We present a case with systemic amyloidosis secondary to immunoglobulin light-chain amyloidosis (AL amyloidosis), which 18F-FDG PET/CT and 99mTc-PYP scintigraphy revealed amyloid deposition in the peritoneum, omentum, and mesentery. AL amyloidosis is characterized by the proliferation of clonal plasma cells and increased production and extracellular accumulation of immunoglobulin light chains, leading to organ malfunction. Even though AL amyloidosis can affect the gastrointestinal system, peritoneal involvement is rarely observed.
View Article and Find Full Text PDFClin Case Rep
November 2024
Department of Internal Medicine, Nepal Medical College and Teaching Hospital Kathmandu University Kathmandu Nepal.
Continuous ambulatory peritoneal dialysis (CAPD) is used for the maintenance dialysis in patients with end stage renal disease. Treatment's complications in CAPD generally exist, of which transudate hydrothorax falls under the minority of the cases. Here, we aim to present a case of a 51 years old female, a newly diagnosed case of chronic kidney disease (CKD) undergoing CAPD for 3 weeks who presented at our institution with complaints of difficulty in breathing.
View Article and Find Full Text PDFQuant Imaging Med Surg
November 2024
Department of Radiology, Hospital Clínic de Barcelona, University of Barcelona (UB), Barcelona, Spain.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!