Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The objective of this study was to characterize vitellogenin (VTG) protein in male fathead minnow (Pimephales promelas) mucus compared with more conventional measures in plasma and mRNA isolated from liver. To assess the intensity and duration of changes in mucus VTG concentrations, male fathead minnows were exposed to 17α-ethinylestradiol (EE2) for 7 days with a subsequent depuration period of 14 days. The experiment was conducted in a flow-through system to maintain a consistent concentration of EE2 at a nominal EC concentration of 2.5 ng/L and high concentration of 10 ng/L as a positive control. Mucus, plasma and liver were sampled at regular intervals throughout the study. Relative abundance of vtg mRNA increased after 2 days of exposure and returned to control levels after 4 days of depuration. VTG protein concentration displayed similar induction kinetics in both mucus and plasma, however, it was found to be significantly increased after 2 days of exposure using the mucus-based assays and 7 days with the plasma-based assay. Significantly elevated levels of VTG were detected by both assays throughout the 14-day depuration period. The elimination of the laborious plasma collection step in the mucus-based workflow allowed sampling of smaller organisms where blood volume is limiting. It also resulted in significant gains in workflow efficiency, decreasing sampling time without loss of performance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9109421 | PMC |
http://dx.doi.org/10.1016/j.ecoenv.2022.113428 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!