A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of cytological examination of Tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy. | LitMetric

Although Tao brush has become one of the most studied and used endometrial cytological samplers, concerns remain about the adequacy of the cytological sample compared with definitive histology. We aimed to assess accuracy of cytological examination from Tao brush sampling in diagnosing endometrial premalignancy and malignancy through a systematic review and meta-analysis. Seven electronic databases were searched from January 2000 to July 2021 for all studies which allowed assessment of accuracy of Tao brush in diagnosing endometrial premalignancy and malignancy. We calculated sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-), diagnostic odds ratio (DOR) and area under the curve (AUC) on summary receiver operating characteristic (SROC) curve. Five studies with 774 patients were included. In diagnosing endometrial premalignancy and malignancy, cytological examination from Tao brush endometrial sampling showed pooled sensitivity of 0.95 (95% CI, 0.90-0.98), specificity of 0.92 (95% CI, 0.90-0.94), LR+ of 12.73 (95% CI, 3.94-41.18), LR- of 0.09 (95% CI, 0.05-0.18), DOR of 184.84 (95% CI, 24.37-1401.79), AUC of 0.9757 (standard error: 0.013). In conclusion, cytological examination from Tao brush seems to have a high diagnostic accuracy and might be proposed as both screening and diagnostic tool. However, further studies are necessary to confirm these findings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9790584PMC
http://dx.doi.org/10.1002/ijgo.14204DOI Listing

Publication Analysis

Top Keywords

tao brush
24
cytological examination
16
examination tao
16
diagnosing endometrial
16
endometrial premalignancy
16
premalignancy malignancy
16
accuracy cytological
8
brush endometrial
8
endometrial sampling
8
sampling diagnosing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!