The roughness of material surfaces is of greatest relevance for applications. These include wear, friction, fatigue, cytocompatibility, or corrosion resistance. Today's descriptors of the International Organization for Standardization show varying performance in discriminating surface roughness patterns. We introduce here a set of surface parameters which are extracted from the appropriate persistence diagram with enhanced discrimination power. Using the finite element method implemented in Abaqus Explicit 2019, we modelled American Rolling Mill Company pure iron specimens (volume 1.5 × 1.5 × 1.0 mm) exposed to a shot peening procedure. Surface roughness evaluation after each shot impact and single indents were controlled numerically. Conventional and persistence-based evaluation is implemented in Python code and available as open access supplement. Topological techniques prove helpful in the comparison of different shot peened surface samples. Conventional surface area roughness parameters might struggle in distinguishing different shot peening surface topographies, in particular for coverage values > 69%. Above that range, the calculation of conventional parameters leads to overlapping descriptor values. In contrast, lifetime entropy of persistence diagrams and Betti curves provide novel, discriminative one-dimensional descriptors at all coverage ranges. We compare how conventional parameters and persistence parameters describe surface roughness. Conventional parameters are outperformed. These results highlight how topological techniques might be a promising extension of surface roughness methods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8976008PMC
http://dx.doi.org/10.1038/s41598-022-09551-9DOI Listing

Publication Analysis

Top Keywords

surface roughness
20
conventional parameters
12
surface
9
conventional surface
8
shot peened
8
shot peening
8
topological techniques
8
roughness
7
parameters
7
shot
5

Similar Publications

: Caries or iatrogenic thermal trauma of the teeth have a significant impact on the dental pulp structure connected with stimulation of angiogenesis and lymphangiogenesis. Therefore, the aim of the study was to identify the difference in the rate of heat dissipation by vessels present in the dental pulp. : Freshly extracted healthy ( = 10) and carious ( = 14) molars and premolars were cut on a diamond saw and subjected to active thermographic examination and then subjected to lymphoscintigraphy and X-ray examination.

View Article and Find Full Text PDF

Electrocatalysis: From Planar Surfaces to Nanostructured Interfaces.

Chem Rev

January 2025

Department of Chemical & Biomolecular Engineering, University of California, Irvine, California 92697, United States.

The reactions critical for the energy transition center on the chemistry of hydrogen, oxygen, carbon, and the heterogeneous catalyst surfaces that make up electrochemical energy conversion systems. Together, the surface-adsorbate interactions constitute the electrochemical interphase and define reaction kinetics of many clean energy technologies. Practical devices introduce high levels of complexity where surface roughness, structure, composition, and morphology combine with electrolyte, pH, diffusion, and system level limitations to challenge our ability to deconvolute underlying phenomena.

View Article and Find Full Text PDF

Colloidal gels, ubiquitous in industrial applications, can undergo reversible solid-to-liquid transitions. Recent work demonstrates that adding surface roughness to primary particles enhances the toughness and influences the self-healing properties of colloidal gels. In the present work, we first use colloidal probe atomic force microscopy (CP-AFM) to assess the quantitative changes in adhesive and frictional forces between thermoresponsive particles as a function of their roughness.

View Article and Find Full Text PDF

Aim: The aim of this study was to compare the surface roughness and color stability of polyetheretherketone (PEEK) with those of conventional interim prosthetic materials like polymethylmethacrylate, bis-acrylic composite, and rubberized diurethane dimethacrylate, following immersion in solutions of varying pH value.

Materials And Methods: A total of 320 circular discs with 10 mm diameter and 2 mm height were divided based on the fabrication ( = 80)-group A: polymethylmethacrylate; group B: bis-acrylic composite; group R: rubberized diurethane; and group P: hot-pressed PEEK-and were subjected to baseline measurement of roughness ( = 40) and color ( = 40) using 3D profilometer and UV-Vis spectrophotometer, respectively. Later, 10 samples from each group were immersed in distilled water, black coffee, green tea, and Pepsi, respectively, for 120 days, and measurements of roughness and color were repeated.

View Article and Find Full Text PDF

Background/purpose: Early osseointegration of titanium (Ti) dental implants relies on the surface topography. Surface modification of Ti seeks to enhance bone regeneration around implants. Acid etching is the simple, less technique sensitive and cost-effective technique for surface treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!