Electrochemical aptamer-based (EAB) sensors support the real-time, high frequency measurement of pharmaceuticals and metabolites in-situ in the living body, rendering them a potentially powerful technology for both research and clinical applications. Here we explore quantification using EAB sensors, examining the impact of media selection and temperature on measurement performance. Using freshly-collected, undiluted whole blood at body temperature as both our calibration and measurement conditions, we demonstrate accuracy of better than ± 10% for the measurement of our test bed drug, vancomycin. Comparing titrations collected at room and body temperature, we find that matching the temperature of calibration curve collection to the temperature used during measurements improves quantification by reducing differences in sensor gain and binding curve midpoint. We likewise find that, because blood age impacts the sensor response, calibrating in freshly collected blood can improve quantification. Finally, we demonstrate the use of non-blood proxy media to achieve calibration without the need to collect fresh whole blood.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8976050PMC
http://dx.doi.org/10.1038/s41598-022-09070-7DOI Listing

Publication Analysis

Top Keywords

electrochemical aptamer-based
8
eab sensors
8
body temperature
8
temperature calibration
8
temperature
5
improved calibration
4
calibration electrochemical
4
aptamer-based sensors
4
sensors electrochemical
4
aptamer-based eab
4

Similar Publications

Nucleic Acid Aptamer-Based Sensors for Bacteria Detection: A Review.

Bioessays

January 2025

Department of Biology and Medicine ,college of Chemistry and Chemical Engineering, Central South University, Changsha, China.

Bacteria have a significant impact on human production and life, endangering human life and health, so rapid detection of infectious agents is essential to improve human health. Aptamers, which are pieces of oligonucleotides (DNA or RNA) have been applied to biosensors for bacteria detection due to their high affinity, selectivity, robust chemical stability, and their compatibility with various signal amplification and signal transduction mechanisms. In this review, we summarize the different bacterial aptamers selected in recent years using SELEX technology and discuss the differences in optical and electrochemical bacterial aptamer sensors.

View Article and Find Full Text PDF
Article Synopsis
  • Bacterial infectious diseases pose a significant public health challenge, especially with rising antibiotic resistance, making fast detection of pathogens essential for control measures.
  • Current methods rely on culture techniques, which are time-consuming and require special equipment, leading to a need for alternative detection methods that can quickly identify whole bacteria without culture.
  • Aptamer-based assays are emerging as a promising alternative, offering benefits such as stability, specificity, and cost-effectiveness, with various detection techniques like optical and electrochemical methods enhancing their utility in diagnosing bacterial infections.
View Article and Find Full Text PDF

Electrochemical aptamer-based biosensors (E-aptasensors) are emerging platforms for point-of-care (POC) detection of complex biofluids. Human saliva particularly offers a noninvasive matrix and unprecedented convenience for detecting illicit drugs, such as cocaine. However, the sensitivity of cocaine E-aptasensors is significantly compromised in saliva.

View Article and Find Full Text PDF

Although various sensors specifically developed for target analytes are available, affordable biosensing solutions with broad applicability are limited. In this study, a cost-effective biosensor for detecting human epidermal growth factor receptor 2 (HER2) was developed using custom-made gold leaf electrodes (GLEs). A novel strategy for antibody immobilization on a gold surface, for the first time mediated by protein L and HER2-specific antibody trastuzumab, was examined using commercial screen-printed gold electrodes and GLEs.

View Article and Find Full Text PDF

Aptamer-based DNAzyme walker electrochemical biosensing strategy for Acinetobacter baumannii detection.

Bioelectrochemistry

December 2024

Department of Laboratory Medicine, The Affiliated Hospital of Southwest Medical University, 25 Taiping Street, Luzhou 646000, Sichuan, China; Sichuan Province Engineering Technology Research Center of Molecular Diagnosis of Clinical Diseases, China; Molecular Diagnosis of Clinical Diseases Key Laboratory of Luzhou, Sichuan, China. Electronic address:

In this study, an innovative electrochemical biosensor was developed for the rapid, specific, and sensitive detection of Acinetobacter baumannii without the need for sample pretreatment. The biosensor utilized an aptamer as a specific capture probe for A. baumannii and employed a self-powered DNAzyme walker cleavage cycle reaction to achieve signal amplification.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!