Background: Osteoporotic fractures are common, and their incidence are increasing worldwide. The first fracture doubles the risk of new fractures. Despite that, up to 80% of patients with a fragility fracture are evaluated or treated to reduce the risk of new fractures.

Aims: To evaluate the results of the operation of the hospital Fracture Liaison Service (FLS) and to analyze the clinical characteristics of the patients attending the service in its first 2 years of operation and to estimate the fracture risk reduction ratio.

Methods: The FLS managed patients older than 50 years who were admitted with a low-energy trauma fracture between January 2017 and April 2018. This management consists in a full medical evaluation, nutritional and physical activity guidance, and specific osteoporosis treatment, if needed.

Results: We monitored and treated 135 patients. Forty percent of them had a previous fracture and only 20.3% of them received treatment to prevent new fractures. On Kaplan-Meier analysis, the estimated incidence of new fractures over 24 months was 12.1% (95% CI 7.2-20.8%), indicating that the percentage of patients without new fractures due to bone fragility during treatment was estimated at 87.9% (95% CI 79.2-92.8%).

Conclusions: The evaluation and treatment of patients who sustained a fragility fracture to prevent a secondary fracture is effective in reducing the risk of new fractures in high-risk patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8974802PMC
http://dx.doi.org/10.1007/s40520-022-02116-wDOI Listing

Publication Analysis

Top Keywords

fracture
9
incidence fractures
8
patients
8
fracture liaison
8
liaison service
8
risk fractures
8
fragility fracture
8
fractures
6
fractures clinical
4
clinical profile
4

Similar Publications

Collagen/polyvinyl alcohol scaffolds combined with platelet-rich plasma to enhance anterior cruciate ligament repair.

Biomater Adv

December 2024

College of Biological Science and Engineering, Fuzhou University, No. 2 Xueyuan Road, Fuzhou 350108, China; Fujian Key Laboratory of Medical Instrument and Pharmaceutical Technology, Fuzhou University, No. 2 Xueyuan Road, Fuzhou 350108, China. Electronic address:

In anterior cruciate ligament (ACL) repair methods, the continuous enzymatic erosion of synovial fluid can impede healing and potentially lead to repair failure, as well as exacerbate articular cartilage wear, resulting in joint degeneration. Inspired by the blood clot during medial collateral ligament healing, we developed a composite scaffold comprising collagen (1 %, w/v) and polyvinyl alcohol (5 %, w/v) combined with platelet-rich plasma (PRP). The composite scaffold provides a protective barrier against synovial erosion for the ruptured ACL, while simultaneously facilitating tissue repair, thereby enhancing the efficacy of ACL repair techniques.

View Article and Find Full Text PDF

Objective: To quantify the otolaryngologic diagnoses encountered in outpatient clinics by otolaryngology-head and neck surgery (OHNS) residents during their 5 years of postgraduate training.

Methods: This is a retrospective review at a single institution following 5 consecutive graduating resident cohorts throughout their training. The electronic health record was queried for OHNS clinic encounters from 2013 through 2022 during which the resident physicians were included as the visit provider or assistant to an attending physician.

View Article and Find Full Text PDF

TiRobot-assisted versus freehand femoral neck system placement in the treatment of femoral neck fractures: a systematic review and meta-analysis.

J Robot Surg

January 2025

The Third Ward of Orthopaedic Department, General Hospital of Ningxia Medical University, 804 Shengli South Street, Hui Autonomous Region, Yinchuan, Ningxia, 750004, People's Republic of China.

The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis.

View Article and Find Full Text PDF

Adequate intraoperative visualization is mandatory for implant application in pelvic ring injuries. Several fluoroscopic X-ray views are in practical use. The gold standard primary X-ray is the anteroposterior view of the pelvis.

View Article and Find Full Text PDF

Background: Hand injuries are a leading cause of emergency department visits. Recent trends in hand trauma management reflect a shift toward outpatient care, driven by factors such as a shortage of skilled personnel or increasing cost pressures. This study analyzed these trends to propose updated management strategies for hand injuries.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!