Background: Real-time evaluation of blood perfusion is important when selecting the site of anastomosis during thoracic esophagectomy. This study investigated a novel imaging technology that assesses tissue oxygen saturation (StO2) in the gastric conduit and examined its efficacy.

Methods: Fifty-one patients undergoing thoracic esophagectomy for esophageal cancer who underwent intraoperative StO2 endoscopic imaging to assess the gastric conduit for the optimal site of anastomosis were examined. Efficacy of oxygen saturation imaging and patient outcomes were analyzed.

Results: All 51 patients underwent esophagectomy without intraoperative problems. Mean StO2 in the gastric tube was highest at the pre-pylorus area and then gradually decreased proceeding toward the tip. StO2 was well preserved in areas supplied by the right gastroepiploic artery but low in other areas. Anastomotic sites were selected based on StO2 imaging and tension considerations; most were located within 3 cm of the end of the right gastroepiploic artery. Three patients developed postoperative anastomotic leakage (5.8%). Mean StO2 at the point of anastomosis was significantly lower in the patients who experienced leakage than in those who did not (P = 0.04).

Conclusion: Intraoperative endoscopic StO2 imaging is useful in esophageal cancer patients undergoing thoracic esophagectomy to determine the optimal site for anastomosis to minimize the risk of anastomotic leakage.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-022-09199-6DOI Listing

Publication Analysis

Top Keywords

thoracic esophagectomy
16
oxygen saturation
12
gastric conduit
12
site anastomosis
12
novel imaging
8
imaging technology
8
sto2 gastric
8
patients undergoing
8
undergoing thoracic
8
esophageal cancer
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!