Subacute right ventricular perforation by a pacemaker lead is a rare complication. Although occasionally asymptomatic, complicated cases are usually evidently symptomatic. Here, we report a 70-year-old man presented with mild left-sided chest pain three days after permanent pacemaker implantation. Suspected of ventricular perforation by the pacemaker lead on chest X-ray, device interrogation revealed non-corroborative parameters. This warranted a computed tomography (CT) scan, which confirmed the diagnosis, detected hemopneumothorax, and helped plan surgical intervention. The patient underwent surgical management with the placement of an epicardial pacemaker lead and was discharged after five days. Our case illustrates a rare report of subtle clinical presentation in a patient with subacute right ventricular perforation by a pacemaker lead complicated by hemopneumothorax. It further recapitulates the role of CT scan in providing definitive diagnostic information in managing such a patient. Anticipation of such a presentation is essential for primary care physicians, who are often a first contact point for a patient in the community. This requires a high index of suspicion in such patients presenting with minimal symptoms. Early recognition and timely referral by a family physician may prevent untoward consequences of device-related complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8963646 | PMC |
http://dx.doi.org/10.4103/jfmpc.jfmpc_448_21 | DOI Listing |
Micromachines (Basel)
January 2025
Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.
Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.
View Article and Find Full Text PDFVet Sci
January 2025
Department of Clinics, Faculty of Veterinary Medicine, "Ion Ionescu de la Brad" Iasi University of Life Sciences, 700490 Iasi, Romania.
A 3-year-old spayed male mixed-breed Labrador presented to the Emergency and Critical Care Unit with lethargy, loss of appetite, vomiting, a recent history of presyncopal episodes, and severe exercise intolerance. On admission, the patient had bradycardia, low blood pressure, and mild abdominal pain. Serum biochemistry information revealed severe hyperkalemia, hyponatremia, hypoglycemia, and mildly increased liver and kidney parameters.
View Article and Find Full Text PDFBMC Cardiovasc Disord
January 2025
Department of Hematology and Oncology, Shenzhen Children's Hospital of China Medical University, Shenzhen, 518038, China.
Purpose: Pacemaker-related infections are serious complications of cardiac implantable electronic devices (CIEDs). This case report aims to describe the occurrence of pacemaker pocket infection and recurrent ventricular tachycardia (VT) in a Chinese amateur violinist with sick sinus syndrome (SSS), and to explore the possible connection between occupational habits and the infection, as well as VT.
Methods: A 76-year-old male violinist with a Biotronik Evia DR dual-chamber pacemaker presented with syncope and signs of a pacemaker pocket infection three years after implantation.
Cureus
December 2024
Department of Cardiology, Shariati Hospital, School of Medicine, Tehran University of Medical Sciences, Tehran, IRN.
Pulmonary thromboembolism (PTE) is the third most common cause of acute cardiovascular disease, which can lead to high morbidity and mortality if left untreated. Anatomical and electrophysiological variations and obesity may complicate timely diagnosis and delay required management. While computed tomography pulmonary angiography (CTPA) remains the most accurate diagnostic tool, initial assessments using electrocardiography (ECG) or echocardiography can be helpful in early suspicion.
View Article and Find Full Text PDFJ Cardiol Cases
October 2024
Second Division of Cardiology, Pisa University Hospital, Pisa, Italy.
Unlabelled: Corrected transposition of the great arteries (c-TGA) is a congenital abnormality characterized by atrioventricular (AV) and ventriculoarterial discordance, associated with early and late-onset conduction disturbances. We report the case of a c-TGA patient affected by congenital complete AV block, with right ventricular lead malfunction with prolonged dwell time and two abandoned leads. He underwent leadless VDD pacemaker implantation at an unusual site (i.