Purpose: To evaluate the inter-observer and inter-method reliability for patellar height measurements between conventional radiographs (CR) and magnetic resonance imaging (MRI) using one or two slices.

Methods: This was a reliability study, with 60 patients divided in two groups: 30 patients with patellar instability (patella group) and 30 patients with anterior cruciate ligament or meniscus injury (control group). CR and MRI were evaluated by two independent observers. Insall-Salvati index (IS) and Caton-Deschamps index (CD) were measured using three different methods: CR, one-slice MRI or two-slice MRI. Intra-class correlation coefficients (ICC) were calculated for inter-observer reliability and inter-method reliability. Bland-Altman agreement was also calculated.

Results: The inter-observer reliability was very good for the IS with ICCs of 0.93, 0.84 and 0.82, for the CR, one-slice MRI and two-slice MRI, respectively. Similarly, for the CD the ICCs were good, 0.76, 0.80 and 0.75 for the CR, one-slice MRI and two-slice MRI, respectively. No differences were found between the patella and the control group. The inter-method analysis results were: ICCs for IS (0.83, 0.86, 0.93) and CD (0.72, 0.82, 0.83), for the comparisons of CR/one-slice MR, CR/two-slice MRI and one-slice MRI/two-slice MRI, respectively. The Bland-Altman mean differences showed an 8% and a 7% increase on IS values with one-slice MRI and two-slice MRI compared to CR results, while the increase was of 9% and 1% in CD for the respective comparisons with CR.

Conclusion: MRI can overestimate patellar height compared to CR, as much as an 8% increase in Insall-Salvati values when using one- or two-slice MRI measurements, and up to a 9% increase in Caton-Deschamps value when using the one-slice MRI method. It is recommended to use the CR as the preferred method when measuring patellar height.

Level Of Evidence: III.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-022-06953-0DOI Listing

Publication Analysis

Top Keywords

one-slice mri
20
two-slice mri
20
mri two-slice
16
mri
15
patellar height
12
magnetic resonance
8
resonance imaging
8
height compared
8
inter-method reliability
8
control group
8

Similar Publications

Article Synopsis
  • This study compares the effectiveness of two-dimensional (2D) and three-dimensional (3D) radiomics models in predicting lymphovascular invasion (LVI) status in esophageal squamous cell carcinoma (ESCC) patients.
  • A total of 224 patients were analyzed, with their data split into training and testing sets, and radiomics features were extracted from CT images to develop the predictive models.
  • Results showed that the 3D model outperformed the 2D model in terms of accuracy, specificity, and positive predictive value, demonstrating its potential as a better tool for LVI prediction in clinical settings.
View Article and Find Full Text PDF

Sample strategies for the assessment of the apparent diffusion coefficient in single large intracranial space-occupying lesions of dogs and cats.

Front Vet Sci

May 2024

Department of Diagnostics and Clinical Services, Clinic for Diagnostic Imaging, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.

Diffusion-weighted imaging is increasingly available for brain investigation. Image interpretation of intracranial space-occupying lesions often includes the derived apparent diffusion coefficient (ADC) analysis. In human medicine, ADC can help discriminate between benign and malignant lesions in intracranial tumors.

View Article and Find Full Text PDF

Purpose: To evaluate the feasibility of using a deep learning (DL) model to generate fat-suppression images and detect abnormalities on knee magnetic resonance imaging (MRI) through the fat-suppression image-subtraction method.

Material And Methods: A total of 45 knee MRI studies in patients with knee disorders and 12 knee MRI studies in healthy volunteers were enrolled. The DL model was developed using 2-dimensional convolutional neural networks for generating fat-suppression images and subtracting generated fat-suppression images without any abnormal findings from those with normal/abnormal findings and detecting/classifying abnormalities on knee MRI.

View Article and Find Full Text PDF

The eye possesses a paravascular solute transport pathway that is driven by physiological pulsations, resembling the brain glymphatic pathway. We developed synchronous multimodal imaging tools aimed at measuring the driving pulsations of the human eye, using an eye-tracking functional eye camera (FEC) compatible with magnetic resonance imaging (MRI) for measuring eye surface pulsations. Special optics enabled integration of the FEC with MRI-compatible video ophthalmoscopy (MRcVO) for simultaneous retinal imaging along with functional eye MRI imaging (fMREye) of the BOLD (blood oxygen level dependent) contrast.

View Article and Find Full Text PDF

Accelerated liver water T mapping using single-shot continuous inversion-recovery spiral imaging.

NMR Biomed

May 2024

Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.

Purpose: Liver T mapping techniques typically require long breath holds or long scan time in free-breathing, need correction for inhomogeneities and process composite (water and fat) signals. The purpose of this work is to accelerate the multi-slice acquisition of liver water selective T (wT) mapping in a single breath hold, improving the k-space sampling efficiency.

Methods: The proposed continuous inversion-recovery (IR) Look-Locker methodology combines a single-shot gradient echo spiral readout, Dixon processing and a dictionary-based analysis for liver wT mapping at 3 T.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!