The development of minimally invasive procedures and implant materials has improved the fixation strength of implants and is less traumatic in surgery. The purpose of this study was to propose a novel "double-point fixation" for calcaneal fractures and compare its biomechanical stability with the traditional "three-point fixation." A three-dimensional finite element foot model with a Sanders type IIIAB calcaneal fracture was developed based on clinical images comprising bones, plantar fascia, ligaments, and encapsulated soft tissue. Double-point and three-point fixation resembled the surgical procedure with a volar distal radius plate and calcaneal locking plate, respectively. The stress distribution, fracture displacement, and change of the Böhler angle and Gissane's angle were estimated by a walking simulation using the model, and the predictions between the double-point and three-point fixation were compared at heel-strike, midstance, and push-off instants. Double-point fixation demonstrated lower bone stress (103.3 199.4 MPa), but higher implant stress (1,084.0 577.9 MPa). The model displacement of double-point fixation was higher than that of three-point fixation (3.68 2.53 mm). The displacement of the posterior joint facet (0.127 0.150 mm) and the changes of the Böhler angle (0.9° 1.4°) and Gissane's angle (0.7° 0.9°) in double-point fixation were comparably lower. Double-point fixation by volar distal radius plates demonstrated sufficient and favorable fixation stability and a lower risk of postoperative stress fracture, which may potentially serve as a new fixation modality for the treatment of displaced intra-articular calcaneal fractures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8959616 | PMC |
http://dx.doi.org/10.3389/fbioe.2022.791554 | DOI Listing |
Int Urol Nephrol
March 2024
Department of Urology, The First Affiliated Hospital of Zhejiang Chinese Medicine University, 54 Youdian Road, Hangzhou, 310000, Zhejiang, China.
Objectives: The aim of this study was to demonstrate the feasibility of a modified sling mid-urethral suspension + subcutaneous tunnel-double point fixation technique for the treatment of male urinary incontinence and to preliminarily evaluate the short-term clinical efficacy of this technique.
Patients And Methods: The clinical data of patients treated with the modified sling mid-urethral suspension + subcutaneous tunnel-double point fixation technique using a Pelvimesh pelvic floor repair patch as a sling were collected. The primary evaluation criteria were surgery-related indicators and daily urinal pad usage before and after treatment, and the secondary evaluation criteria were the corresponding incontinence scores and the results of surgery-related questionnaires.
Front Bioeng Biotechnol
March 2022
Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China.
The development of minimally invasive procedures and implant materials has improved the fixation strength of implants and is less traumatic in surgery. The purpose of this study was to propose a novel "double-point fixation" for calcaneal fractures and compare its biomechanical stability with the traditional "three-point fixation." A three-dimensional finite element foot model with a Sanders type IIIAB calcaneal fracture was developed based on clinical images comprising bones, plantar fascia, ligaments, and encapsulated soft tissue.
View Article and Find Full Text PDFArthrosc Tech
December 2020
Hospital Italiano de Buenos Aires, Buenos Aires City, Argentina.
The optimal management of anterior shoulder instability continues to be a challenge. The presence of an anterior glenoid rim fracture in the context of a glenohumeral dislocation, also called "bony Bankart lesion," can alter therapeutic behavior. Reduction and fixation of the bone fragment has been shown to greatly reduce the risk of recurrence once bone consolidation is achieved.
View Article and Find Full Text PDFAm J Sports Med
November 2013
George S. Athwal, The Hand and Upper Limb Centre, St Joseph's Health Care London, 268 Grosvenor Street, London, ON, Canada, N6A 4L6.
Background: As an alternative to the standard single-point suture-anchor technique, a suture-bridge technique has been described for the treatment of bony Bankart fractures. There is, however, little evidence supporting one technique over the other. Purpose/
Hypothesis: To compare the failure strength, fixation stability, and loading mechanics of the 2 techniques for the fixation of bony Bankart fractures.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!