We report the first case of aortic pseudoaneurysm following bioprosthetic aortic valve replacement in an immunocompetent host. Infection was complicated by septic emboli to multiple organs. Despite aggressive surgical intervention and antifungal therapy, infection progressed. We review the literature on invasive infection to inform diagnosis and management.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8947321 | PMC |
http://dx.doi.org/10.1093/ofid/ofab536 | DOI Listing |
Radiol Case Rep
March 2025
Department of Medical Imaging, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, Jeddah, Saudi Arabia.
Subclavian artery pseudoaneurysm (SAP) is a rare but lethal diagnosis, and an important condition that should be detected and managed imperatively. SAP has been seldom described in the literature, explaining the lack of concrete management guidelines. Herein we present a case study of a 63-year-old man with SAP post a transcatheter aortic valve implantation (TAVI) done 8 days prior to current presentation.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Department of Radiology, The Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, China.
Medicine (Baltimore)
January 2025
Gastroenterology, Chongqing University Cancer Hospital, Chongqing, China.
Rationale: Aortoesophageal fistula (AEF) is an exceedingly rare yet critically life-threatening condition, with mortality rates nearing 100% if not addressed promptly. AEF often develops in the context of thoracic aortic aneurysms, esophageal malignancies, or as a complication of foreign body ingestion and prior thoracic aortic surgeries. This study reports an exceptionally severe and clinically rare case of AEF associated with a pseudaneurysm induced by esophageal stenting.
View Article and Find Full Text PDFWe present the case of a 74-year-old female patient with a 50 mm ascending aortic aneurysm who underwent ascending aorta replacement. During routine open heart surgery, suboptimal flow in the cardiopulmonary bypass circuit, led to the discovery of a type B aortic dissection with substantial flow in the false lumen. Conservative management was chosen, focusing on blood pressure control in the ICU.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
January 2025
Heart Clinic Zurich, Hirslanden, Witellikerstrasse 40, Zurich, 8032, Switzerland.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!