AI Article Synopsis

  • - The study introduces a new 3D fast spin-echo (FSE) imaging technique called MSDE-CUBE-fTED that may be a better alternative to traditional 2D FSE sequences for examining the brachial plexus.
  • - In a comparison involving 14 volunteers, the MSDE-CUBE-fTED sequence outperformed the 2D T2-weighted FSE in all evaluation categories, showing high scores in nerve visualization and diagnostic confidence.
  • - The results indicate that MSDE-CUBE-fTED could replace standard T2- and T1-weighted sequences, as it provided better signal ratios and substantial agreement between radiologists, suggesting strong reliability.

Article Abstract

Objective: To introduce a 3D fast spin-echo (FSE) sequence technique that may replace conventional clinical 2D FSE sequences for examining the brachial plexus.

Materials And Methods: A 3D FSE sequence with motion-sensitized driven equilibrium magnitude preparation, triple-echo Dixon, and outer-volume suppression techniques, dubbed as MSDE-CUBE-fTED, was compared with clinical 2D T2-weighted and T1-weighted FSE sequences on the conventional brachial plexus exam of 14 volunteers. The resulting images were evaluated by two radiologists for fat suppression, blood flow suppression, nerve visualization, scalene muscle shape, surrounding fat planes, and diagnostic confidence. The inter-rater agreement of the reviewers was also measured. In addition, the signal magnitude ratios and contrast-to-noise ratios between nerve-to-vessel, nerve-to-muscle, and fat-to-muscle were compared.

Results: The MSDE-CUBE-fTED sequence scored significantly higher than the T2-weighed FSE sequence in all visualization categories (P < 0.05). Its score was not significantly different from that of the T1-weighted FSE in muscle and fat visualization (P ≥ 0.5). The inter-rater agreements were substantial (Gwet's agreement coefficient ≥ 0.7). The signal magnitude and contrast ratios were significantly higher in the MSDE-CUBE-fTED sequence (P < 0.05).

Conclusion: Our results suggest that the MSDE-CUBE-fTED sequence can make a potential alternative to standard T2- and T1-weighted FSE sequences for examining the brachial plexus.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00256-022-04021-9DOI Listing

Publication Analysis

Top Keywords

fse sequence
12
fast spin-echo
8
brachial plexus
8
fse sequences
8
fse
5
robust fast
4
spin-echo technique
4
technique fast
4
fast examination
4
examination brachial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!