A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Patient-specific instrumentation reduces deviations between planned and postosteotomy humeral retrotorsion and height in shoulder arthroplasty. | LitMetric

Patient-specific instrumentation reduces deviations between planned and postosteotomy humeral retrotorsion and height in shoulder arthroplasty.

J Shoulder Elbow Surg

Shoulder, Elbow and Orthopaedic Sports Medicine, Sonnenhof Orthopaedics, Bern, Switzerland; Shoulder, Elbow Unit, Sportsclinicnumber1, Bern, Switzerland; Shoulder, Elbow and Orthopaedic Sports Medicine, Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, Bern, Switzerland; Campus Stiftung Lindenhof Bern, Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland. Electronic address:

Published: September 2022

Background: Patient-specific instrumentation (PSI) may potentially improve humeral osteotomy in shoulder arthroplasty. The purpose of this study was to compare the deviation between planned and postosteotomy humeral inclination, retrotorsion, and height in shoulder arthroplasty, using PSI vs. standard cutting guides (SCG).

Methods: Twenty fresh-frozen cadaveric specimens were allocated to undergo humeral osteotomy using either PSI or SCG, such that the 2 groups have similar age, gender, and side. Preosteotomy computed tomography (CT) scan was performed and used for the 3-dimensional (3D) planning. The osteotomy procedure was performed using a PSI designed for each specimen or an SCG depending on the group. A postosteotomy CT scan was performed. The preosteotomy and postosteotomy 3D CT scan reconstructions were superimposed to calculate the deviation between planned and postosteotomy inclination, retrotorsion, and height. Outliers were defined as cases with 1 or more of the following deviations: >5° inclination, >10° retrotorsion, and >3 mm height. The deviation and outliers in inclination, retrotorsion, and height were compared between the 2 groups.

Results: The deviations between planned and postosteotomy parameters were similar among the PSI and SCG groups for inclination (P = .260), whereas they were significantly greater in the SCG group for retrotorsion (P < .001) and height (P = .003). There were 8 outliers in the SCG group, compared with only 1 outlier in the PSI group (P = .005). Most outliers in the SCG group were due to deviation >10° in retrotorsion.

Conclusion: After 3D planning, PSI had less deviation between planned and postosteotomy humeral retrotorsion and height, relative to SCG.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2022.02.025DOI Listing

Publication Analysis

Top Keywords

retrotorsion height
24
planned postosteotomy
20
postosteotomy humeral
12
shoulder arthroplasty
12
deviation planned
12
inclination retrotorsion
12
patient-specific instrumentation
8
deviations planned
8
humeral retrotorsion
8
height shoulder
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!