AI Article Synopsis

  • Recent advancements in robotic-assisted bronchoscopy (RAB) have shown varied success in biopsying peripheral pulmonary nodules (PPNs), leading to a study aimed at identifying factors that improve biopsy outcomes.
  • A preclinical trial using a cadaver model tested how different distances and techniques impact the likelihood of successfully puncturing targeted PPNs using RAB.
  • Findings indicated that the closer the robotic catheter was to the nodule (within 10 mm), the higher the success rate of obtaining a central target hit, highlighting distance as a key factor for effective biopsy.

Article Abstract

Background: Despite recent advances in guided bronchoscopy, the yield of bronchoscopic biopsy of a peripheral pulmonary nodule (PPN) remains highly variable.

Objective: The aim of the study was to evaluate which features of robotic assisted bronchoscopy (RAB) contribute to a successful biopsy in a cadaver model.

Methods: A preclinical, prospective, single-blinded trial using a ventilated human cadaveric model assessed the successful puncture of implanted pulmonary nodules using various localization techniques with RAB. The different approaches included positioning the robotic catheter at predefined distances from the target nodule (<10 mm, 10-20 mm, 20-30 mm), bronchoscopist correction of divergence between the software virtual map and bronchoscopic view if observed, and impact of fluoroscopy and radial endobronchial ultrasound (rEBUS). The primary endpoint was a central target hit (defined as an inner 2/3 target puncture) verified by cone-beam computed tomography.

Results: Thirty-eight RAB procedures were performed to target 16 PPNs. Median nodule size was 16.2 mm. All targets were located in the outer 1/3 of the lung with a bronchus sign in 31.3%. Central target hit rates were improved when the robotic catheter tip was closer to the nodule (<10 mm 68%, 10-20 mm 66%, 20-30 mm 11%, p < 0.001). Multivariable analysis confirmed the strongest predictor of a central target hit was robotic catheter distance to nodule (OR 0.89 per increase in 1 mm, p < 0.001), independent of the presence of a bronchus sign, divergence or concentric rEBUS view.

Conclusions: Utilizing a RAB platform, closer proximity of the robotic catheter to the target nodule results in an increase in peripheral nodule biopsy success.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000522514DOI Listing

Publication Analysis

Top Keywords

pulmonary nodule
8
robotic assisted
8
assisted bronchoscopy
8
accuracy pulmonary
4
nodule sampling
4
sampling robotic
4
bronchoscopy shape
4
shape sensing
4
sensing fluoroscopy
4
fluoroscopy radial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!