A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A cloth-based electrochemiluminescence sensor for determination of salbutamol residues in pork samples. | LitMetric

The fabrication of a cloth-based analytical device combined with electrochemiluminescence detection was established for the rapid determination of salbutamol in pork samples. A hand-coloring method to pattern the hydrophobic chamber was employed, and a three-carbon electrode system was subsequently screen printed onto the patterned cotton chamber. Further modifications of the working electrode surface were conducted using platinum nanoparticles and chitosan solution. The salbutamol enhanced the electrochemiluminescence signal of tris(2,2'-bipyridyl)ruthenium(II) complex in the Britton-Robinson buffer of pH 9.5 and the potential quantitative assay for SAL detection was exhibited. The proposed sensor illustrated a linear calibration curve of the logarithmic SAL concentration in the range of 5 × 10 to 5 × 10 µg L (r > 0.996). A limit of detection of 6.8 ng L was observed. The CAD-ECL sensor was successfully applied for the determination of salbutamol residuals in pork samples. The method validation was performed using the LC-MS method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2022.132786DOI Listing

Publication Analysis

Top Keywords

determination salbutamol
12
pork samples
12
cloth-based electrochemiluminescence
4
electrochemiluminescence sensor
4
sensor determination
4
salbutamol
4
salbutamol residues
4
residues pork
4
samples fabrication
4
fabrication cloth-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!