The purpose of this study is to evaluate the effectiveness of heartbeat error and compensation methods on heart rate variability (HRV) with mobile and wearable sensor devices. The HRV analysis extracts multiple indices related to the heart and autonomic nervous system from beat-to-beat intervals. These HRV analysis indices are affected by the heartbeat interval mismatch, which is caused by sampling error from measurement hardware and inherent errors from the state of human body. Although the sampling rate reduction is a common method to reduce power consumption on wearable devices, it degrades the accuracy of the heartbeat interval. Furthermore, wearable devices often use photoplethysmography (PPG) instead of electrocardiogram (ECG) to measure heart rate. However, there are inherent errors between PPG and ECG, because the PPG is affected by blood pressure fluctuations, vascular stiffness, and body movements. This paper evaluates the impact of these errors on HRV analysis using dataset including both ECG and PPG from 28 subjects. The evaluation results showed that the error compensation method improved the accuracy of HRV analysis in time domain, frequency domain and non-linear analysis. Furthermore, the error compensation by the algorithm was found to be effective for both PPG and ECG.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8927864 | PMC |
http://dx.doi.org/10.1049/htl2.12023 | DOI Listing |
Radiol Med
January 2025
Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
Purpose: To develop an artificial intelligence (AI) algorithm for automated measurements of spinopelvic parameters on lateral radiographs and compare its performance to multiple experienced radiologists and surgeons.
Methods: On lateral full-spine radiographs of 295 consecutive patients, a two-staged region-based convolutional neural network (R-CNN) was trained to detect anatomical landmarks and calculate thoracic kyphosis (TK), lumbar lordosis (LL), sacral slope (SS), and sagittal vertical axis (SVA). Performance was evaluated on 65 radiographs not used for training, which were measured independently by 6 readers (3 radiologists, 3 surgeons), and the median per measurement was set as the reference standard.
Magn Reson Imaging
January 2025
Department of Medical Imaging, Pingyin people's Hospital, Jinan 250400, China.
Magnetic Resonance Imaging is a cornerstone of medical diagnostics, providing high-quality soft tissue contrast through non-invasive methods. However, MRI technology faces critical limitations in imaging speed and resolution. Prolonged scan times not only increase patient discomfort but also contribute to motion artifacts, further compromising image quality.
View Article and Find Full Text PDFSensors (Basel)
January 2025
College of Geoexploration Science and Technology, Jilin University, Changchun 130012, China.
As gravity exploration technology advances, gravity gradient measurement is becoming an increasingly important method for gravity detection. Airborne gravity gradient measurement is widely used in fields such as resource exploration, mineral detection, and oil and gas exploration. However, the motion and attitude changes of the aircraft can significantly affect the measurement results.
View Article and Find Full Text PDFSensors (Basel)
January 2025
College of Science and Technology, Ningbo University, Ningbo 315300, China.
Industrial robotic arms are often subject to significant end-effector pose deviations from the target position due to the combined effects of nonlinear deformations such as link flexibility, joint compliance, and end-effector load. To address this issue, a study was conducted on the analysis and compensation of end-position errors in a six-degree-of-freedom robotic arm. The kinematic model of the robotic arm was established using the Denavit-Hartenberg (DH) parameter method, and a rigid-flexible coupled virtual prototype model was developed using ANSYS and ADAMS.
View Article and Find Full Text PDFSensors (Basel)
January 2025
College of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China.
Under regional environmental conditions such as open-pit mines and construction sites, there are usually fixed GNSS measurement points. Around these fixed stations, there are also mobile GNSS measurement modules. These mobile measurement modules offer advantages such as low power consumption, low cost, and large data volume.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!