A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Numerical investigation of the influence of the source and detector position for optical measurement of lung volume and oxygen content in preterm infants. | LitMetric

There is an urgent need for improved respiratory surveillance of preterm infants. Gas in scattering media absorption spectroscopy (GASMAS) is emerging as a potential clinical cutaneous monitoring tool of lung functions in neonates. A challenge in the clinical translation of GASMAS is to obtain sufficiently high signal-to-noise ratios in the measurements, since the light attenuation is high in human tissue. Previous GASMAS studies on piglets have shown higher signal quality with an internal source, as more light propagates through the lung and the loss due to scattering and absorption is less. In this article we simulated light propagation with an intratracheal and a dermal source, and investigated the signal quality and lung volume probed. The results suggest that GASMAS has the potential to measure respiratory volumes; and the sensitivity is higher for an intratracheal source which also enables to probe most of the lung.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbio.202200041DOI Listing

Publication Analysis

Top Keywords

lung volume
8
preterm infants
8
signal quality
8
lung
5
numerical investigation
4
investigation influence
4
source
4
influence source
4
source detector
4
detector position
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!