Vital sign monitoring systems are essential in the care of hospitalized neonates. Due to the immaturity of their organs and immune system, premature infants require continuous monitoring of their vital parameters and sensors need to be directly attached to their fragile skin. Besides mobility restrictions and stress, these sensors often cause skin irritation and may lead to pressure necrosis. In this work, we show that a contactless radar-based approach is viable for breathing monitoring in the Neonatal intensive care unit (NICU). For the first time, different scenarios common to the NICU daily routine are investigated, and the challenges of monitoring in a real clinical setup are addressed through different contributions in the signal processing framework. Rather than just discarding measurements under strong interference, we present a novel random body movement mitigation technique based on the time-frequency decomposition of the recovered signal. In addition, we propose a simple and accurate frequency estimator which explores the harmonic structure of the breathing signal. As a result, the proposed radar-based solution is able to provide reliable breathing frequency estimation, which is close to the reference cabled device values most of the time. Our findings shed light on the strengths and limitations of this technology and lay the foundation for future studies toward a completely contactless solution for vital signs monitoring.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8956695 | PMC |
http://dx.doi.org/10.1038/s41598-022-08836-3 | DOI Listing |
Sensors (Basel)
November 2024
Águeda School of Technology and Management (ESTGA), Instituto de Telecomunicações, Universidade de Aveiro, 3750-127 Águeda, Portugal.
In recent years, with the increased interest in smart home technology and the increased need to remotely monitor patients due to the pandemic, demand for contactless systems for vital sign measurements has also been on the rise. One of these kinds of systems are Doppler radar systems. Their design is composed of several choices that could possibly have a significant impact on their overall performance, more specifically those focused on the measurement of cardiac activity.
View Article and Find Full Text PDFFront Physiol
November 2024
Vitalthings AS, Trondheim, Norway.
Introduction: Continuous monitoring of respiratory rate in hospital wards can provide early detection of clinical deterioration, thereby reducing mortality, reducing transfers to intensive care units, and reducing the hospital length of stay. Despite the advantages of continuous monitoring, manually counting every 1-12 h remains the standard of care in most hospital wards. The objective of this study was to validate continuous respiratory rate measurements from a radar-based contactless patient monitor [Vitalthings Guardian M10 (Vitalthings AS, Norway)] in a hospital ward.
View Article and Find Full Text PDFBMC Palliat Care
November 2024
Department of Palliative Medicine, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
Background: Heart rate (HR) monitoring is a medical standard to provide information about a patient's health status. In palliative care, relationship and social engagement are crucial therapeutic concepts. For fear of disrupting communication, social contact, and care, continuous HR monitoring is underutilised despite its potential to inform on symptom burden and therapeutic effects.
View Article and Find Full Text PDFPLoS One
November 2024
Division of Psychiatry, Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, United Kingdom.
Sleep is crucial for the healthy development of adolescents, yet many suffer from chronic sleep deprivation. Over the transition to and course of adolescence there are known changes to sleep patterns e.g.
View Article and Find Full Text PDFBiomed Phys Eng Express
November 2024
The University of Electro-Communications, Tokyo, Japan.
Using radar for non-contact measuring human vital signs has garnered significant attention due to its undeniable benefits. However, achieving reasonably good accuracy in contactless measurement senarios is still a technical challenge.The proposed method includes two stages.