Purpose: A pointwise encoding time reduction with radial acquisition (PETRA) sequence was optimized to detect empty catheters in interstitial (HDR) brachytherapy with clinically acceptable spatial accuracy for the first time. Image quality and catheter detectability were assessed in phantoms, and the feasibility of PETRA's clinical implementation was assessed on a gynecological cancer patient.

Methods And Results: Empty catheters embedded in a gelatin phantom displayed positive signal on PETRA and more accurate cross-sections than on clinically employed T2-weighted sequences, differing by 0.4 mm on average from their nominal 2 mm diameter. PETRA presented minimal susceptibility differences and a symmetric metal artifact, contrary to the clinical sequences. The PETRA-CT catheter tip position differences assessed by a treatment planning system (TPS) were < 1 mm. PETRA also detected an interstitial template with empty catheters penetrating a poultry phantom and fused very well with CT. Interstitial catheter positional difference between PETRA and CT images was < 1 mm on average, increasing with distance from isocenter. All interstitial catheters and the employed interstitial template were detected on PETRA images of an endometrial adenocarcinoma patient. Empty needles were traceable using a TPS, with higher spatial resolution and more favorable contrast than on T2-weighted images used for contouring. A treatment plan could be produced by combining information from PETRA for catheter detection and from T2-weighted images for tumor and organs delineation.

Conclusions: PETRA detected successfully and accurately interstitial catheters in phantoms. Its first clinical implementation shows a potential for MR-only treatment planning in interstitial HDR brachytherapy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brachy.2022.01.003DOI Listing

Publication Analysis

Top Keywords

hdr brachytherapy
12
empty catheters
12
petra
9
pointwise encoding
8
encoding time
8
time reduction
8
reduction radial
8
radial acquisition
8
acquisition petra
8
catheter detection
8

Similar Publications

Background: High-dose-rate (HDR) brachytherapy using Iridium-192 as a radiation source is widely employed in cancer treatment to deliver concentrated radiation doses while minimizing normal tissue exposure. In this treatment, the precision with which the sealed radioisotope source is delivered significantly impacts clinical outcomes.

Purpose: This study aims to evaluate the feasibility of a new four-dimensional (4D) in vivo source tracking and treatment verification system for HDR brachytherapy using a patient-specific approach.

View Article and Find Full Text PDF

Purpose: To compare the clinical outcomes of two different schedules of modern image-guided adaptive brachytherapy (IGABT) in patients underwent chemoradiotherapy (CCRT) and high-dose rate (HDR) brachytherapy (BT) for locally advanced cervical cancer treated (LACC) METHODS AND MATERIALS: Data from medical records of all consecutive patients with histologically proven cervical cancer (FIGO 2018 stage IB-IVA) treated by HDR-BT after CCRT at our institution between 2016 and 2021 were reviewed.

Results: Two hundred and 8 patients with LACC FIGO 2018 stages (IB 20.7%; II 26.

View Article and Find Full Text PDF

: To analyze the results of interstitial (IRT) high-dose-rate (HDR) brachytherapy (BT) in the primary treatment of patients with unresectable superior sulcus tumors (SST) combined with external beam radiotherapy (EBRT). : Between 2013 and 2023, seven patients with unresectable SST were treated with combined BT and EBRT with or without concomitant chemotherapy. The patients' median age was 64 years (range, 49-79 years) and median tumor volume was 146.

View Article and Find Full Text PDF

Purpose: High-dose-rate brachytherapy (HDR-BT) combined with external beam radiotherapy (EBRT) is an effective treatment for patients with high- and very-high-risk prostate cancer. We sought to identify the factors associated with reduced biochemical recurrence rates following HDR-BT.

Methods: A total of 304 patients with high- or very-high-risk prostate cancer who underwent HDR-BT and EBRT were analyzed.

View Article and Find Full Text PDF

Comparison of HDR-brachytherapy and tomotherapy for the treatment of non-melanoma skin cancers of the head and neck.

Radiother Oncol

December 2024

Medical Physics Unit, IRCCS, Istituto Romagnolo per lo Studio dei Tumori (IRST) "Dino Amadori", Italy. Electronic address:

Purpose: This study aims to investigate and compare High Dose Rate Brachytherapy (HDR-BT) with Helical Tomotherapy (HT) treatment plans. The focus is on small target volumes near radiation-sensitive organs in the ocular region, to evaluate the advantages of these techniques in treating skin cancer.

Methods: This retrospective observational analysis included patients who underwent skin cancer HDR-BT Freiburg flap treatment between 2019 and 2023.