Objective: To report outcomes following endovascular revascularisation for severe aorto-iliac occlusive disease (AIOD) using covered (CS) or bare metal (BMS) stent(s).
Methods: This was a retrospective cohort study including patients who underwent treatment with CS or BMS for AIOD between November 2012 and March 2020 in 12 European centres. Outcome measures included death, freedom from target lesion revascularisation (TLR), major amputation, and major adverse cardiac and cerebrovascular events (MACCE).
Results: Overall, 252 patients (53% males; mean age 65 ± 10 years) were included (102 with a bare metal and 150 with a covered aortic stent); 122 (48%) presented with chronic limb threatening ischaemia (CLTI). Severe arterial calcification was noted in > 65% of patients, 70% presented with Trans-Atlantic Societies Consensus (TASC) D lesions, 32% and 46% had aortic or iliac chronic total occlusion (CTO), respectively. Median follow up was 17 months (range 6 - 40; none lost to follow up). Median inpatient stay was two days (range two to four). During the first 30 days, two patients died (both with covered aortic stents, because of cardiovascular events), none required TLR, two (1%) patients had a major amputation (all presented with CLTI), and three (1%) had a MACCE. At 17 months, mortality (BMS 14% vs. CS 7%, hazard ratio [HR] 0.97, 95% confidence interval [CI] 0.42 - 2.26, p = .94, log rank test) and TLR (11% vs. 10%, HR 1.98, 95% CI 0.89 - 4.43, p = .095) did not differ statistically significantly between the two groups; only three patients had a major limb amputation during late follow up (all with a covered stent). In a multivariable model, the use of an aortic CS did not influence TLR. In a conditional Cox regression, however, the concomitant use of aortic and iliac CSs was associated with improved freedom from TLR.
Conclusion: Endovascular reconstruction with aortic CSs or BMSs for severe AIOD showed comparable midterm performance. The use of both aortic and iliac CSs seems to be associated with reduced TLR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejvs.2021.12.020 | DOI Listing |
Materials (Basel)
December 2024
Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Maria-Reiche-Strasse 2, 01109 Dresden, Germany.
Coated metallic stents are the next generation of metallic stents with improved surface properties. To evaluate the degradation behavior of stents in vitro, different in vitro degradation models can be applied: (i) static immersion test: degradation under static fluid condition, (ii) fluid dynamic test: degradation under flowing fluid, and (iii) electrochemical corrosion test: degradation under the influence of electric potential. During these experimental procedures, stents interact with the simulated blood plasma, and degradation products are formed in the form of depositions on the stent surface, likewise in vivo experiments.
View Article and Find Full Text PDFMolecules
January 2025
College of Sciences, Shanghai University, Shanghai 200444, China.
Dihydromyricetin (DMY), as the main active ingredient in , is a naturally occurring flavonoid that has attracted extensive attention for its multiple biological activities. For the quick and accurate measurement of DMY, a novel electrochemical sensor based on a glassy carbon electrode (GCE) modified with a cobalt metal-organic framework (Co-MOF) was proposed in this work. The Co-MOF was synthesized via a single-step hydrothermal process using Co(NO)·6HO.
View Article and Find Full Text PDFAppl Biochem Biotechnol
January 2025
Department of Botany, Maharshi Dayanand University, Rohtak, 124001, India.
Cellulase was effectively immobilized onto an epoxy-bound chitosan-modified zinc metal-organic framework (epoxy/ZIF-8/CS/cellulase) support, yielding a conjugation rate of 0.64 ± 0.02 mg/cm2 and retaining 80.
View Article and Find Full Text PDFPhys Chem Chem Phys
January 2025
Departamento de Física Aplicada - Instituto de Ciencia de Materiales, Matter at High Pressure (MALTA) Consolider Team, Universidad de Valencia, Edificio de Investigación, C/Dr Moliner 50, Burjassot, 46100, Valencia, Spain.
The production of hydrogen (H) fuel through electrocatalysis is emerging as a sustainable alternative to conventional and environmentally harmful energy sources. However, the discovery of cost-effective and efficient materials for this purpose remains a significant challenge. In this study, we explore the potential of the transition-metal-substituted YNS MXene as a promising candidate for hydrogen production through the hydrogen evolution reaction (HER).
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!