Lock-in vibrothermography has proven to be very useful to characterizing kissing cracks producing ideal, homogeneous, and compact heat sources. Here, we approach real situations by addressing the characterization of non-compact (strip-shaped) heat sources produced by open cracks and inhomogeneous fluxes. We propose combining lock-in vibrothermography data at several modulation frequencies in order to gather penetration and precision data. The approach consists in inverting surface temperature amplitude and phase data by means of a least-squares minimization algorithm without previous knowledge of the geometry of the heat source, only assuming knowledge of the vertical plane where it is confined. We propose a methodology to solve this ill-posed inverse problem by including in the objective function penalty terms based on the expected properties of the solution. These terms are described in a comprehensive and intuitive manner. Inversions of synthetic data show that the geometry of non-compact heat sources is identified correctly and that the contours are rounded due to the penalization. Inhomogeneous smoothly varying fluxes are also qualitatively retrieved, but steep variations of the flux are hard to recover. These findings are confirmed by inversions of experimental data taken on calibrated samples. The proposed methodology is capable of identifying heat sources generated in lock-in vibrothermography experiments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8955162 | PMC |
http://dx.doi.org/10.3390/s22062336 | DOI Listing |
Sensors (Basel)
March 2022
Departamento de Física Aplicada, Escuela de Ingeniería de Bilbao, Universidad del País Vasco UPV/EHU, Plaza Ingeniero Torres Quevedo 1, 48013 Bilbao, Spain.
Lock-in vibrothermography has proven to be very useful to characterizing kissing cracks producing ideal, homogeneous, and compact heat sources. Here, we approach real situations by addressing the characterization of non-compact (strip-shaped) heat sources produced by open cracks and inhomogeneous fluxes. We propose combining lock-in vibrothermography data at several modulation frequencies in order to gather penetration and precision data.
View Article and Find Full Text PDFMaterials (Basel)
May 2021
Mechanics of Materials and Structures (UGent-MMS), Department of Materials, Textiles and Chemical Engineering (MaTCh), Ghent University, Technologiepark-Zwijnaarde 46, 9052 Zwijnaarde, Belgium.
This paper proposes an efficient non-destructive testing technique for composite materials. The proposed vibro-thermal wave radar (VTWR) technique couples the thermal wave radar imaging approach to low-power vibrothermography. The VTWR is implemented by means of a binary phase modulation of the vibrational excitation, using a 5 bit Barker coded waveform, followed by matched filtering of the thermal response.
View Article and Find Full Text PDFSensors (Basel)
January 2017
Department of Electrical and Computer Engineering, Computer Vision and Systems Laboratory, Laval University, 1065 av. de la Médecine, QC G1V 0A6, Canada.
n/a.
View Article and Find Full Text PDFSensors (Basel)
May 2016
Department of Electrical and Computer Engineering, Computer Vision and Systems Laboratory, Laval University, 1065 av. de la Médecine, Quebec City, QC G1V 0A6, Canada.
In this article, optical excitation thermographic techniques, including pulsed thermography and lock-in thermography, were used to detect foreign object defect (FOD) and delamination in CFRP. Then, vibrothermography as an ultrasonic excitation technique was used to detect these defects for the comparative purposes. Different image processing methods, including cold image subtraction (CIS), principal component thermography (PCT), thermographic signal reconstruction (TSR) and Fourier transform (FT), were performed.
View Article and Find Full Text PDFRev Sci Instrum
September 2012
Department of Industrial Chemistry and Materials Engineering, University of Messina, Contrada di Dio, 98166 Messina, Italy.
This paper reports one of the first experimental results on the application of ultrasound activated lock-in vibrothermography for quantitative assessment of buried flaws in complex cast parts. The use of amplitude modulated ultrasonic heat generation allowed selective response of defective areas within the part, as the defect itself is turned into a local thermal wave emitter. Quantitative evaluation of hidden damages was accomplished by estimating independently both the area and the depth extension of the buried flaws, while x-ray 3D computed tomography was used as reference for sizing accuracy assessment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!