A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hold that pose: capturing cervical dystonia's head deviation severity from video. | LitMetric

Objective: Deviated head posture is a defining characteristic of cervical dystonia (CD). Head posture severity is typically quantified with clinical rating scales such as the Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS). Because clinical rating scales are inherently subjective, they are susceptible to variability that reduces their sensitivity as outcome measures. The variability could be circumvented with methods to measure CD head posture objectively. However, previously used objective methods require specialized equipment and have been limited to studies with a small number of cases. The objective of this study was to evaluate a novel software system-the Computational Motor Objective Rater (CMOR)-to quantify multi-axis directionality and severity of head posture in CD using only conventional video camera recordings.

Methods: CMOR is based on computer vision and machine learning technology that captures 3D head angle from video. We used CMOR to quantify the axial patterns and severity of predominant head posture in a retrospective, cross-sectional study of 185 patients with isolated CD recruited from 10 sites in the Dystonia Coalition.

Results: The predominant head posture involved more than one axis in 80.5% of patients and all three axes in 44.4%. CMOR's metrics for head posture severity correlated with severity ratings from movement disorders neurologists using both the TWSTRS-2 and an adapted version of the Global Dystonia Rating Scale (rho = 0.59-0.68, all p <0.001).

Conclusions: CMOR's convergent validity with clinical rating scales and reliance upon only conventional video recordings supports its future potential for large scale multisite clinical trials.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9082391PMC
http://dx.doi.org/10.1002/acn3.51549DOI Listing

Publication Analysis

Top Keywords

head posture
28
head
9
posture severity
8
clinical rating
8
rating scales
8
rating scale
8
predominant head
8
posture
7
severity
6
hold pose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!