During the γ-radiation sterilization process, the levels of radiation exposure to a medical device must be carefully monitored to achieve the required sterilization without causing deleterious effects on its intended physical and chemical properties. To address this issue, here we have demonstrated the development of an all-printed disposable low-cost sensor that exploits the change in electrical impedance of a semi-interpenetrating polymer network (SIPN) composed of poly(vinyl alcohol) (PVA) and poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) as a functional polymer composite for radiation sterilization monitoring applications. Specifically, the PEDOT:PSS acts as the electrically conductive medium, while the PVA provides the ductility and stability of the printed sensors. During irradiation exposure, chain scission and cross-linking events occur concurrently in the PEDOT:PSS and PVA polymer chains, respectively. The concurrent scissoring of the PEDOT polymer and cross-linking of the PVA polymer network leads to the formation of a stable SIPN with reduced electrical conductivity, which was verified through FTIR, Raman, and TGA analysis. Systematic studies of different ratios of PEDOT:PSS and PVA mixtures were tested to identify the optimal ratio that provided the highest radiation sensitivity and stability performance. The results showed that PEDOT:PSS/PVA composites with 10 wt % PVA produced sensors with relative impedance changes of 30% after 25 kGy and up to 370% after 53 kGy (which are two of the most commonly used radiation exposure levels for sterilization applications). This composition showed high electrical impedance stability with less than ±5% change over 18 days after irradiation exposure. These findings demonstrate the feasibility of utilizing a printing technology for scalable manufacturing of low-cost, flexible radiation sensors for more effective monitoring of radiation sterilization processes.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.1c02105DOI Listing

Publication Analysis

Top Keywords

radiation sterilization
12
polymer composite
8
composite radiation
8
sterilization monitoring
8
radiation exposure
8
electrical impedance
8
polymer network
8
irradiation exposure
8
pedotpss pva
8
pva polymer
8

Similar Publications

Background: The study aimed to describe a new Ommaya reservoir implantation method in late-onset SMA patients, assessing its safety and effectiveness under standard clinical conditions.

Methods: Prospective observational study. Lumbar intrathecal access was unfeasible due to significant scoliosis and prior spinal surgeries with instrumentation.

View Article and Find Full Text PDF

Environmental radiation is one of the key causes of the increased prevalence of infertility among couples. This type of radiation can be ionizing or non-ionizing. While ionizing radiation is known to cause sterility in both males and females, the role of low-energy non-ionizing radiation is still debated.

View Article and Find Full Text PDF

Inverse dose protraction effects of low-LET radiation: evidence and significance.

Mutat Res Rev Mutat Res

January 2025

Radiation Epidemiology Branch, National Cancer Institute, MD 20892-9778, USA; Faculty of Health, Science and Technology, Oxford Brookes University, Headington Campus, OX3 0BP, UK.

Biological effects of ionizing radiation vary not merely with total dose but also with temporal dose distribution. Sparing dose protraction effects, in which dose protraction reduces effects of radiation have widely been accepted and generally assumed in radiation protection, particularly for stochastic effects (e.g.

View Article and Find Full Text PDF

In women after hematopoietic stem cell transplantation (HSCT), complications associated with the original disease and therapies used both before and after transplantation often occur, which significantly affects their quality of life. The most common gynaecological complications include secondary cancers, premature ovarian insufficiency (POI), infertility and chronic graft-versus-host disease (cGVHD). Cervical cancer is the most common secondary genital cancer in patients after HSCT.

View Article and Find Full Text PDF

Purpose: Due to the extensive use of radiation in various fields, such as food safety, sterilizing surgical materials, and medical diagnostics, it is essential to minimize radiation exposure for both patients and healthcare professionals, even at low doses. To meet this requirement, a composite film has been developed using polyvinyl alcohol (PVA) polymer and nitro blue tetrazolium (NBT) dye to measure low radiation doses effectively.

Methods: Various concentrations of NBT dye (ranging from 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!