Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The posterior wall (PW) has been proposed as a standard target for ablation beyond pulmonary vein antral isolation (PVI) in patients with persistent atrial fibrillation (AF). However, studies have shown inconsistent outcomes with the addition of PW ablation. The presence or absence of low voltage on the PW may explain these inconsistencies. We evaluated whether PW ablation based on the presence or absence of low voltage improves long-term arrhythmia-free outcomes.
Methods: We retrospectively reviewed 5-year follow-up in 152 consecutive patients who received either standard ablation (SA) with PVI alone or PVI + PW ablation (PWA) based on physician discretion (n = 77) or voltage-guided ablation (VGA) with PVI and addition of PWA only if low voltage was present on the PW (n = 75).
Results: The two groups were well matched for baseline characteristics. At 5-year follow-up, 64% of patients receiving VGA were atrial tachyarrhythmia (AT)/AF free compared to 34% receiving SA (HR 0.358 p < .005). PWA had similar AF recurrence in SA and VGA groups (0.30 vs. 0.27 p = .96) but higher AT recurrence when comparing SA and VGA groups (0.39 vs. 0.15 p = .03). In multivariate analysis, both VGA and PWA predicted AF arrhythmia-free survival (HR 0.33, p = .001 and HR 0.20, p = .008, respectively). For AT, VGA predicted arrhythmia-free survival (HR 0.22, p = .028), while PWA predicted AT recurrence (HR 4.704, p = .0219).
Conclusion: VGA of the posterior wall ablation beyond PVI in persistent AF significantly improves long-term arrhythmia-free survival when compared with non-voltage-guided ablation. PW ablation without voltage-guidance reduced AF recurrence but at the cost of a higher incidence of AT.