Non-T2 severe asthma and chronic obstructive pulmonary disease (COPD) are airway chronic inflammatory disorders with a poor response to corticosteroids. LAS194046, a novel pan-Janus kinase (JAK) inhibitor, shows inhibitory effects on T2 allergic lung inflammation in rats. In this work we analyze the effects of LAS194046, fluticasone propionate and their combination in neutrophils from non-T2 severe asthma and COPD patients in vitro. Neutrophils from 23 healthy subjects, 23 COPD and 21 non-T2 severe asthma patients were incubated with LAS194046 (0.01 nM-1 µM), fluticasone propionate (0.1 nM-1 µM) or their combination and stimulated with lipopolysaccharide (LPS 1 µM). LAS194046 shows similar maximal % inhibition and potency inhibiting IL-8, MMP-9 and superoxide anion release in neutrophils from healthy, COPD and asthma. Fluticasone propionate suppresses mediator release only in neutrophils from healthy patients. The combination of LAS194046 with fluticasone propionate shows synergistic anti-inflammatory and anti-oxidant effects. The mechanisms involved in the synergistic effects of this combination include the increase of MKP1 expression, decrease of PI3Kδ, the induction of glucocorticoid response element and the decrease of ERK1/2, P38 and JAK2/STAT3 phosphorylation compared with monotherapies. In summary, LAS194046 shows anti-inflammatory effects in neutrophils from COPD and severe non-T2 asthma patients and induces synergistic anti-inflammatory effects when combined with fluticasone propionate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8948298PMC
http://dx.doi.org/10.1038/s41598-022-09241-6DOI Listing

Publication Analysis

Top Keywords

fluticasone propionate
20
severe asthma
16
non-t2 severe
12
neutrophils healthy
12
asthma copd
8
copd patients
8
patients vitro
8
las194046 fluticasone
8
asthma patients
8
release neutrophils
8

Similar Publications

Objective: To compare the effectiveness and safety of budesonide-glycopyrrolate-formoterol, a twice daily metered dose inhaler, and fluticasone-umeclidinium-vilanterol, a once daily dry powder inhaler, in patients with chronic obstructive pulmonary disease (COPD) treated in routine clinical practice.

Design: New user cohort study.

Setting: Longitudinal commercial US claims data.

View Article and Find Full Text PDF

The concentrations of nasal nitric oxide (nNO) vary in patients with chronic rhinosinusitis (CRS) supposedly depending upon whether the paranasal ostia are open or obstructed. Our aim was to assess whether nNO levels and their response to topical xylometazoline (a local vasoconstrictor used to alleviate nasal congestion) in patients with CRS differ between those with open or obstructed ostia and if the results were altered by the use of nasal corticosteroids. Methodology: Sixty-six patients with CRS (43% with nasal polyps) or recurrent acute rhinosinusitis and 23 healthy controls were included.

View Article and Find Full Text PDF

This study aimed to evaluate the pharmacokinetic characteristics, safety, and bioequivalence of 2 formulations of fluticasone nasal spray in healthy Chinese subjects. A single-center, randomized, open-label, single-dose, 2-formulation, 2-sequence, 2-period crossover bioequivalence study was conducted under fasting conditions. A total of 120 healthy male and female subjects were enrolled, of which 119 subjects completed the entire study.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to analyze the cost-effectiveness of budesonide/formoterol compared to other asthma treatments at Mexico's National Institute for Respiratory Diseases.
  • Budesonide/formoterol had a lower average cost per patient ($733.36 USD) compared to fluticasone/vilanterol ($767.24 USD), and it showed a significant reduction in exacerbations with an incremental cost-effectiveness ratio (ICER) of $613.31 USD for better management.
  • Overall, budesonide/formoterol was found to be a very cost-effective treatment option, suggesting it could reduce healthcare costs associated with emergency visits and hospitalizations despite fewer exacerbations per patient.
View Article and Find Full Text PDF

In this study we evaluated the effects of flow lamination on aerosol flow dynamics and deposition at the exit point in testing models with spatial barriers (narrowing or curving).We compared ModiFlow (MF) to an idealized Standard Spacer (SS) in their efficiency of delivery of aerosolized medication (fluticasone) across different types of spatial barriers. Fluticasone propionate HFA Inhaler from Prasco Labs 220 µg per actuation was used to deliver 1 spray in each test tube.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!