A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Continuous VOCs Monitoring in Saturated and Unsaturated Zones Using Thermal Desorber and Gas Chromatography: System Development and Field Application. | LitMetric

Subsurface VOC monitoring has been mainly based on manual sampling, transport, and analysis, which would require a sufficient amount of samples to ensure data accuracy and reliability, and additional costs to ensure sample quality. Therefore, a continuous on-site monitoring system is desirable for accurate measurement and subsequent risk assessment. In this study, benzene, toluene, ethylbenzene, and xylene (BTEX) were continuously monitored by the system based on a thermal desorber (TD) and gas chromatography (GC) in an oil-contaminated site that consisted of saturated and unsaturated zones. For the saturated zone, fully automated groundwater sampling and purging processes were performed, and the gasified samples were applied to the TD-GC system. For the unsaturated zone, the gaseous sample in the site was directly applied to the TD-GC system. After verifying the accuracy and precision of the monitoring system, the continuous monitoring system was successfully operated for more than a month in the field. The monitoring system used in this study is applicable to other sites for continuous monitoring, thus providing a scientific background for advanced risk assessment and policy development.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950982PMC
http://dx.doi.org/10.3390/ijerph19063400DOI Listing

Publication Analysis

Top Keywords

monitoring system
16
saturated unsaturated
8
unsaturated zones
8
thermal desorber
8
desorber gas
8
gas chromatography
8
system
8
risk assessment
8
applied td-gc
8
td-gc system
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!