Cam-type femoroacetabular impingement (FAI) syndrome is a painful, structural hip disorder. Herein, we investigated hip joint mechanics through in vivo, dynamic measurement of the bone-to-bone distance between the femoral head and acetabulum in patients with cam FAI syndrome and morphologically screened controls. We hypothesized that individuals with cam FAI syndrome would have larger changes in bone-to-bone distance compared to the control group, which we would interpret as altered joint mechanics as signified by greater movement of the femoral head as it articulates within the acetabulum. Seven patients with cam FAI syndrome and 11 asymptomatic individuals with typical morphology underwent dual fluoroscopy imaging during level and inclined walking (upward slope). The change in bone-to-bone distance between femoral and acetabular bone surfaces was evaluated for five anatomical regions of the acetabulum at each timepoint of gait. Linear regression analysis of the bone-to-bone distance considered two within-subject factors (activity and region) and one between-subjects factor (group). Across activities, the change in minimum bone-to-bone distance was 1.38-2.54 mm for the cam FAI group and 1.16-1.84 mm for controls. In all regions except the anterior-superior region, the change in bone-to-bone distance was larger in the cam group than the control group (p ≤ 0.024). An effect of activity was detected only in the posterior-superior region where larger changes were noted during level walking than incline walking. Statement of clinical significance: Patients with cam FAI syndrome exhibit altered hip joint mechanics during the low-demand activity of walking; these alterations could affect load transmission, and contribute to pain, tissue damage, and osteoarthritis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9508282 | PMC |
http://dx.doi.org/10.1002/jor.25332 | DOI Listing |
J Orthop Res
August 2024
Amsterdam Shoulder and Elbow Centre of Expertise (ASECE), Amsterdam, The Netherlands.
In unstable shoulders, excessive anteroinferior position of the humeral head relative to the glenoid can lead to a dislocation. Measuring humeral head position could therefore be valuable in quantifying shoulder laxity. The aim of this study was to measure (1) position of the humeral head relative to the glenoid and (2) joint space thickness during passive motion in unstable shoulders caused by traumatic anterior dislocations and in contralateral uninjured shoulders.
View Article and Find Full Text PDFJ Orthop Res
August 2024
Institute of Orthopaedics and Musculoskeletal Science, University College London, London, UK.
J Orthop Res
April 2024
Department of Orthopaedic Surgery, Duke University School of Medicine, Durham, North Carolina, USA.
There is limited data quantifying the influence of running on hip cartilage mechanics. The goal of this investigation was to quantify changes in hip joint bone-to-bone distance in response to a 3-mile treadmill run. We acquired magnetic resonance (MR) images of the dominant hip of eight young, asymptomatic runners (five males, three females) before and immediately after they ran 3 miles at a self-selected pace on a level treadmill.
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2023
Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics and Guangdong Engineering Research Center for Translation of Medical 3D Printing Application and National Virtual and Reality Experimental Education Center for Medical Morphology (Southern Medical University) and National Experimental Education Demonstration Center for Basic Medical Sciences (Southern Medical University) and National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China.
To use a novel method to simulate a moving hip model. Then, measure the dynamic bone-to-bone distance, and analyze the ischiofemoral space (IFS) of patients diagnosed with ischiofemoral impingement syndrome (IFI) during dynamic activities. Nine healthy subjects and 9 patients with IFI were recruited to collect MRI images and motion capture data.
View Article and Find Full Text PDFJ Orthop Res
January 2023
Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA.
Cam-type femoroacetabular impingement (FAI) syndrome is a painful, structural hip disorder. Herein, we investigated hip joint mechanics through in vivo, dynamic measurement of the bone-to-bone distance between the femoral head and acetabulum in patients with cam FAI syndrome and morphologically screened controls. We hypothesized that individuals with cam FAI syndrome would have larger changes in bone-to-bone distance compared to the control group, which we would interpret as altered joint mechanics as signified by greater movement of the femoral head as it articulates within the acetabulum.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!