Cam-type femoroacetabular impingement (FAI) syndrome is a painful, structural hip disorder. Herein, we investigated hip joint mechanics through in vivo, dynamic measurement of the bone-to-bone distance between the femoral head and acetabulum in patients with cam FAI syndrome and morphologically screened controls. We hypothesized that individuals with cam FAI syndrome would have larger changes in bone-to-bone distance compared to the control group, which we would interpret as altered joint mechanics as signified by greater movement of the femoral head as it articulates within the acetabulum. Seven patients with cam FAI syndrome and 11 asymptomatic individuals with typical morphology underwent dual fluoroscopy imaging during level and inclined walking (upward slope). The change in bone-to-bone distance between femoral and acetabular bone surfaces was evaluated for five anatomical regions of the acetabulum at each timepoint of gait. Linear regression analysis of the bone-to-bone distance considered two within-subject factors (activity and region) and one between-subjects factor (group). Across activities, the change in minimum bone-to-bone distance was 1.38-2.54 mm for the cam FAI group and 1.16-1.84 mm for controls. In all regions except the anterior-superior region, the change in bone-to-bone distance was larger in the cam group than the control group (p ≤ 0.024). An effect of activity was detected only in the posterior-superior region where larger changes were noted during level walking than incline walking. Statement of clinical significance: Patients with cam FAI syndrome exhibit altered hip joint mechanics during the low-demand activity of walking; these alterations could affect load transmission, and contribute to pain, tissue damage, and osteoarthritis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9508282PMC
http://dx.doi.org/10.1002/jor.25332DOI Listing

Publication Analysis

Top Keywords

bone-to-bone distance
28
fai syndrome
20
cam fai
20
change bone-to-bone
12
joint mechanics
12
patients cam
12
cam-type femoroacetabular
8
femoroacetabular impingement
8
dual fluoroscopy
8
hip joint
8

Similar Publications

In unstable shoulders, excessive anteroinferior position of the humeral head relative to the glenoid can lead to a dislocation. Measuring humeral head position could therefore be valuable in quantifying shoulder laxity. The aim of this study was to measure (1) position of the humeral head relative to the glenoid and (2) joint space thickness during passive motion in unstable shoulders caused by traumatic anterior dislocations and in contralateral uninjured shoulders.

View Article and Find Full Text PDF
Article Synopsis
  • - The study investigates changes in bone shape and implant position one year after total hip arthroplasty using custom 3D-printed cups in patients with severe bone defects (Paprosky type IIIB).
  • - Employing different co-registration techniques with pre- and post-operative CT scans, the researchers measured shifts in implant position and bone morphology, yielding median distances of 2.3 mm for implants and 2.4 mm for bone shape changes.
  • - The findings indicate that post-surgery implant movement and bone remodeling are normal and occur to a comparable degree, highlighting the need for careful monitoring by surgeons and engineers in these cases.
View Article and Find Full Text PDF

There is limited data quantifying the influence of running on hip cartilage mechanics. The goal of this investigation was to quantify changes in hip joint bone-to-bone distance in response to a 3-mile treadmill run. We acquired magnetic resonance (MR) images of the dominant hip of eight young, asymptomatic runners (five males, three females) before and immediately after they ran 3 miles at a self-selected pace on a level treadmill.

View Article and Find Full Text PDF

A novel method for measurement of dynamic ischiofemoral space based on MRI and motion capture.

Front Bioeng Biotechnol

January 2023

Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics and Guangdong Engineering Research Center for Translation of Medical 3D Printing Application and National Virtual and Reality Experimental Education Center for Medical Morphology (Southern Medical University) and National Experimental Education Demonstration Center for Basic Medical Sciences (Southern Medical University) and National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China.

To use a novel method to simulate a moving hip model. Then, measure the dynamic bone-to-bone distance, and analyze the ischiofemoral space (IFS) of patients diagnosed with ischiofemoral impingement syndrome (IFI) during dynamic activities. Nine healthy subjects and 9 patients with IFI were recruited to collect MRI images and motion capture data.

View Article and Find Full Text PDF

Cam-type femoroacetabular impingement (FAI) syndrome is a painful, structural hip disorder. Herein, we investigated hip joint mechanics through in vivo, dynamic measurement of the bone-to-bone distance between the femoral head and acetabulum in patients with cam FAI syndrome and morphologically screened controls. We hypothesized that individuals with cam FAI syndrome would have larger changes in bone-to-bone distance compared to the control group, which we would interpret as altered joint mechanics as signified by greater movement of the femoral head as it articulates within the acetabulum.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!