Thermal Load and Heat Transfer in Dental Titanium Implants: An Ex Vivo-Based Exact Analytical/Numerical Solution to the 'Heat Equation'.

Dent J (Basel)

BioMAT'X I+D+i (Haidar Lab), Universidad de los Andes, Santiago 7550000, Chile.

Published: March 2022

Introduction: Heat is a kinetic process whereby energy flows from between two systems, hot-to-cold objects. In oro-dental implantology, conductive heat transfer/(or thermal stress) is a complex physical phenomenon to analyze and consider in treatment planning. Hence, ample research has attempted to measure heat-production to avoid over-heating during bone-cutting and drilling for titanium (Ti) implant-site preparation and insertion, thereby preventing/minimizing early (as well as delayed) implant-related complications and failure.

Objective: Given the low bone-thermal conductivity whereby heat generated by osteotomies is not effectively dissipated and tends to remain within the surrounding tissue (peri-implant), increasing the possibility of thermal-injury, this work attempts to obtain an exact analytical solution of the heat equation under exponential thermal-stress, modeling transient heat transfer and temperature changes in Ti implants (fixtures) upon hot-liquid intake.

Materials And Methods: We, via an ex vivo-based model, investigated the impact of the (a) material, (b) location point along implant length, and (c) exposure time of the thermal load on localized temperature changes.

Results: Despite its simplicity, the presented solution contains all the physics and reproduces the key features obtained in previous numerical analyses studies. To the best of our knowledge, this is the first introduction of the intrinsic time, a "proper" time that characterizes the geometry of the dental implant fixture, where we show, mathematically and graphically, how the interplay between "proper" time and exposure time influences temperature changes in Ti implants, under the suitable initial and boundary conditions. This fills the current gap in the literature by obtaining a simplified yet exact analytical solution, assuming an exponential thermal load model relevant to cold/hot beverage or food intake.

Conclusions: This work aspires to accurately complement the overall clinical diagnostic and treatment plan for enhanced bone-implant interface, implant stability, and success rates, whether for immediate or delayed loading strategies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946864PMC
http://dx.doi.org/10.3390/dj10030043DOI Listing

Publication Analysis

Top Keywords

thermal load
12
heat transfer
8
exact analytical
8
analytical solution
8
temperature changes
8
changes implants
8
exposure time
8
"proper" time
8
heat
6
time
5

Similar Publications

Existing support systems for thermal pipeline trenches often fail to meet the specific needs of narrow strips, tight timelines, and short construction periods in urban environments. This study introduces a novel recyclable, non-embedded support system composed of corrugated steel plates, retractable horizontal braces, angle steel, and high-strength bolts designed to address these challenges. The system's effectiveness was validated through prototype testing and optimized using Abaqus finite element simulations.

View Article and Find Full Text PDF

This paper presents the results of experimental tests and computer simulations on the stiffness of composite aluminium mullions used in unitised façades. The elements analysed were subjected to bending in order to simulate the actual operating conditions of aluminium façades subjected to significant wind pressure or suction loads. The basic mechanical and physical properties of the materials from which the analysed type of aluminium façade is made (Aluminium EN AW-6060 in the T66 temper and polyamide PA66 25GF), the test method, and the results obtained are described.

View Article and Find Full Text PDF

The emerging thermoplastic composite material PEKK exhibits superior thermal stability compared to PEEK. In this work, CF/PEKK laminates were fabricated using laser-assisted heating in AFP, and the effects of repass treatment on the mechanical properties and microstructure of the laminates were compared. The results show that after a single repass treatment, the tensile strength of the laminates increased by 28.

View Article and Find Full Text PDF

Fiber-reinforced polymer (FRP) composites are increasingly used in civil engineering for strengthening and repairing existing reinforced concrete (RC) members using externally bonded reinforcement (EBR) and near-surface mounted (NSM) methods. However, the fire performance of FRP-strengthened RC members has been an important issue that should be properly considered in the fire safety design process since FRP composites exhibit significant performance degradation at elevated temperatures. This paper aims to review studies on the fire performance of FRP-strengthened RC members based on the existing research results presented in the literature to provide a comprehensive understanding of key factors influencing the structural behavior of FRP-strengthened RC members under fire conditions.

View Article and Find Full Text PDF

Purpose: To investigate how varying ferrule heights and the number of glass fiber posts affect fracture resistance and behavior of endodontically treated maxillary first premolars with substantial loss of tooth structure.

Materials And Methods: Twenty-four extracted endodontically treated human maxillary first premolars were divided into three groups (n = 8) based on ferrule height and post number. The groups were as follows: premolars of 2 mm ferrule height that were restored with single posts (control group), premolars of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!