Cochlear variability is of key importance for the clinical use of cochlear implants, the most successful neuroprosthetic device that is surgically placed into the cochlear scala tympani. Despite extensive literature on human cochlear variability, few information is available on the variability of the modiolar wall. In the present study, we analyzed 108 corrosion casts, 95 clinical cone beam computer tomographies (CTs) and 15 µCTs of human cochleae and observed modiolar variability of similar and larger extent than the lateral wall variability. Lateral wall measures correlated with modiolar wall measures significantly. ~ 49% of the variability had a common cause. Based on these data we developed a model of the modiolar wall variations and related the model to the design of cochlear implants aimed for perimodiolar locations. The data demonstrate that both the insertion limits relevant for lateral wall damage (approximate range of 4-9 mm) as well as the dimensions required for optimal perimodiolar placement of the electrode (the point of release from the straightener; approximate range of 2-5mm) are highly interindividually variable. The data demonstrate that tip fold-overs of preformed implants likely result from the morphology of the modiolus (with radius changing from base to apex), and that optimal cochlear implantation of perimodiolar arrays cannot be guaranteed without an individualized surgical technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8943032PMC
http://dx.doi.org/10.1038/s41598-022-08731-xDOI Listing

Publication Analysis

Top Keywords

modiolar wall
12
lateral wall
12
cochlear implantation
8
cochlear variability
8
cochlear implants
8
wall measures
8
data demonstrate
8
approximate range
8
cochlear
7
variability
6

Similar Publications

Hypothesis: The objective of this study is to obtain comprehensive morphometric measurements of the incomplete partition type II (IP-II) cochlea to provide a better understanding of intracochlear anatomy and important considerations for electrode selection and insertion.

Background: IP-II is the most common bony inner ear malformation that often requires cochlear implantation. Currently, there is significant controversy on electrode selection due to a lack of research that can provide reliable, high-resolution measurements.

View Article and Find Full Text PDF

A novel therapeutic pathway to the human cochlear nerve.

Sci Rep

November 2024

Department of Surgical Sciences, Otorhinolaryngology and Head and Neck Surgery, Uppsala University, Uppsala, Sweden.

Article Synopsis
  • Traditional methods for accessing the human cochlear nerve are limited due to its location within the skull's bony structure.
  • This study introduces a minimally invasive technique for directly reaching the cochlear nerve to apply new regenerative treatments.
  • Using advanced imaging and anatomical studies, researchers identified a safe pathway to the nerve and successfully validated it on multiple human temporal bones.
View Article and Find Full Text PDF
Article Synopsis
  • A study focused on enhancing cochlear implantation techniques by creating a model-free automated algorithm that accurately segments 3D surfaces of the cochlea from CT scans.
  • The algorithm was validated against manually segmented CT scans, demonstrating high accuracy with a 90% area overlap and minimal average distance discrepancy (0.11 mm).
  • Findings suggest that this new approach enables precise quantitative analysis of cochlear anatomy, providing an objective evaluation of the vertical cochlear trajectory, which challenges traditional categorizations based on shape.
View Article and Find Full Text PDF

Introduction: Preservation of residual hearing after cochlear implantation remains challenging. There are several approaches to preserve residual hearing, but the configuration of the implant electrode array seems to play a major role. Lateral wall electrode arrays are seemingly more favorable in this context.

View Article and Find Full Text PDF

Immuno-surveillance and protection of the human cochlea.

Front Neurol

May 2024

Department of Surgical Sciences, Otorhinolaryngology and Head and Neck Surgery, Uppsala University, Uppsala, Sweden.

Background: Despite its location near infection-prone areas, the human inner ear demonstrates remarkable resilience. This suggests that there are inherent instruments deterring the invasion and spread of pathogens into the inner ear. Here, we combined high-resolution light microscopy, super-resolution immunohistochemistry (SR-SIM) and synchrotron phase contrast imaging (SR-PCI) to identify the protection and barrier systems in the various parts of the human inner ear, focusing on the lateral wall, spiral ganglion, and endolymphatic sac.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!