Background: Electrocorticography (ECoG) arrays are commonly used to record the brain activity both in animal and human subjects. There is a lack of guidelines in the literature as to how the array geometry, particularly the via holes in the substrate, affects the recorded signals. A finite element (FE) model was developed to simulate the electric field generated by neurons located at different depths in the rat brain cortex and a micro ECoG array (μECoG) was placed on the pia surface for recording the neural signal. The array design chosen was a typical array of 8 × 8 circular (100 μm in diam.) contacts with 500 μm pitch. The size of the via holes between the recording contacts was varied to see the effect.

Results: The results showed that recorded signal amplitudes were reduced if the substrate was smaller than about four times the depth of the neuron in the gray matter. The signal amplitude profiles had dips around the via holes and the amplitudes were also lower at the contact sites as compared to the design without the holes; an effect that increased with the hole size. Another noteworthy result is that the spatial selectivity of the multi-contact recordings could be improved or reduced by the selection of the via hole sizes, and the effect depended on the distance between the neuron pair targeted for selective recording and its depth.

Conclusions: The results suggest that the via-hole size clearly affects the recorded neural signal amplitudes and it can be leveraged as a parameter to reduce the inter-channel correlation and thus maximize the information content of neural signals with μECoG arrays.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8935835PMC
http://dx.doi.org/10.1186/s42490-022-00060-4DOI Listing

Publication Analysis

Top Keywords

size holes
8
neural signals
8
neural signal
8
signal amplitudes
8
size
4
holes influence
4
influence amplitude
4
amplitude selectivity
4
neural
4
selectivity neural
4

Similar Publications

Assessment of Photoreceptor Recovery and Visual Function Utilizing Adaptive Optics and Microperimetry in Patients with Surgically Closed Macular Holes.

Photodiagnosis Photodyn Ther

December 2024

Department of Ophthalmology, Tianjin Medical University General Hospital, Tianjin, China, Ministry of Education International Joint Laboratory of Ocular Diseases, Tianjin, China, Tianjin Key Laboratory of Ocular Trauma, Tianjin, China, Tianjin Institute of Eye Health and Eye Diseases, Tianjin, China, China-UK "Belt and Road" Ophthalmology. Electronic address:

Background: This study investigated the association between photoreceptor structural restoration and visual function outcomes in patients undergoing surgery for closed macular holes (MHs). Using adaptive optics scanning laser ophthalmoscopy (AOSLO) and microperimetry, we aimed to provide a more detailed understanding of photoreceptor recovery and visual improvement in closed MHs.

Methods: We conducted a retrospective observational study of 31 eyes of 28 patients who underwent vitrectomy with internal limiting membrane (ILM) peeling to treat idiopathic MHs.

View Article and Find Full Text PDF

Purpose: The management of idiopathic macular holes (iMH) has evolved over time with various modifications in surgical approach. The study aimed to survey the surgeons' preferences in the management of iMH in current times.

Design: Cross-sectional descriptive survey.

View Article and Find Full Text PDF

The study presents the fabrication and superior photoactivity of a ternary g-CN/FeVO/AgBr heterojunction nanocomposite, synthesized via a chemical precipitation method for effective degradation of tetracycline (TC) and Victoria Blue (VB) dye under light illumination. The morphology and the crystal size of the synthesized nanocomposite were characterized by using FESEM and XRD and the calculated grain size (100.39 nm) is larger than the crystal size (48.

View Article and Find Full Text PDF

Acoustic waves provide an effective method for object manipulation in microfluidics, often requiring high-frequency ultrasound in the megahertz range when directly handling microsized objects, which can be costly. Micro-air-bubbles in water offer a solution toward low-cost technologies using low-frequency acoustic waves. Owing to their high compressibility and low elastic modulus, these bubbles can exhibit significant expansion and contraction in response to even kilohertz acoustic waves, leading to resonances with frequencies determined and tuned by air-bubble size.

View Article and Find Full Text PDF

Elementary Exciton Processes of InP/ZnS Quantum Dots Under Applied Pressure.

Nano Lett

December 2024

Graduate School of Science, Kwansei Gakuin University, 1 Gakuen Uegahara, Sanda, Hyogo 669-1330, Japan.

In colloidal quantum dots (QDs), excitons are confined within nanoscale dimensions, and the relaxation of hot electrons occurs through Auger cooling. The behavior of hot electrons is evident under ambient pressure. Nanocrystal characteristics, including their size, are key to determining hot electron behavior because they serve as the stage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!