A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analytical and clinical evaluation of the light-initiated chemiluminescent assays for measurement of human thyroid hormones. | LitMetric

Background: Light-initiated chemiluminescent assay (LiCA) is a new homogeneous immunoassay. The aim of this study was to evaluate the analytical and clinical performance of the assays for the detection of thyroid hormones based on the fully automated LiCA 800 analyzer.

Methods: Analytical validations of the LiCA thyroid assays (TSH, FT3, FT4, T3, and T4) included precision, linearity, analytical sensitivity, interference, and method comparison applying the protocols of the Clinical and Laboratory Standards Institute (CLSI). The diagnostic performance was assessed by the receiver operating characteristic (ROC) curve analysis with different assay schemes for the diagnosis of hyperthyroidism and hypothyroidism.

Results: Within-run and within-lab precisions (%CV) of the five assays ranged from 1.06 to 6.40% at all concentrations evaluated. A satisfactory linearity was verified over the entire measuring range for TSH, T3, and T4 (R > 0.99, change in recovery <10%, p = 0.000 all). Paired-comparison measurements presented a comparable assay for each of the five assays (R > 0.96, median bias <5%, p < 0.0001 all) between LiCA and Cobas across three institutes. The diagnostic accuracy of the LiCA assays for hyperthyroidism or hypothyroidism was quantified by the areas under curves (AUC) as 0.925 or 0.832 with the five-assay panel (TSH, FT3, FT4, T3, and T4) and as 0.921 or 0.811 with the three-assay panel (TSH, FT3, and FT4), respectively. No significant difference was found between the AUC of LiCA and that of DxI, Cobas, or Centaur (p > 0.3 all).

Conclusion: LiCA 800 provides a precise and high-throughput immunoassay platform for detection of thyroid hormones. It is acceptable for clinical use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9102509PMC
http://dx.doi.org/10.1002/jcla.24266DOI Listing

Publication Analysis

Top Keywords

analytical clinical
8
light-initiated chemiluminescent
8
thyroid hormones
8
analytical
4
clinical evaluation
4
evaluation light-initiated
4
assays
4
chemiluminescent assays
4
assays measurement
4
measurement human
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!