Live cell imaging of oxidative stress in human airway epithelial cells exposed to isoprene hydroxyhydroperoxide.

Redox Biol

Public Health and Integrated Toxicology Division, U.S. Environmental Protection Agency, Chapel Hill, NC, USA. Electronic address:

Published: May 2022

Exposure to respirable air particulate matter (PM) in ambient air is associated with morbidity and premature deaths. A major source of PM is the photooxidation of volatile plant-produced organic compounds such as isoprene. Photochemical oxidation of isoprene leads to the formation of hydroperoxides, environmental oxidants that lead to inflammatory (IL-8) and adaptive (HMOX1) gene expression in human airway epithelial cells (HAEC). To examine the mechanism through which these oxidants alter intracellular redox balance, we used live-cell imaging to monitor the effects of isoprene hydroxyhydroperoxides (ISOPOOH) in HAEC expressing roGFP2, a sensor of the glutathione redox potential (E). Non-cytotoxic exposure of HAEC to ISOPOOH resulted in a rapid and robust increase in E that was independent of the generation of intracellular or extracellular hydrogen peroxide. Our results point to oxidation of GSH through the redox relay initiated by glutathione peroxidase 4, directly by ISOPOOH or indirectly by ISOPOOH-generated lipid hydroperoxides. We did not find evidence for involvement of peroxiredoxin 6. Supplementation of HAEC with polyunsaturated fatty acids enhanced ISOPOOH-induced glutathione oxidation, providing additional evidence that ISOPOOH initiates lipid peroxidation of cellular membranes. These findings demonstrate that ISOPOOH is a potent environmental airborne hydroperoxide with the potential to contribute to oxidative burden of human airway posed by inhalation of secondary organic aerosols.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8933716PMC
http://dx.doi.org/10.1016/j.redox.2022.102281DOI Listing

Publication Analysis

Top Keywords

human airway
12
airway epithelial
8
epithelial cells
8
isopooh
5
live cell
4
cell imaging
4
imaging oxidative
4
oxidative stress
4
stress human
4
cells exposed
4

Similar Publications

Background: Continuous Positive Airway Pressure (CPAP) treatment brings more benefits than risks to most coronary heart disease (CHD) patients with obstructive sleep apnea (OSA). However, the pathophysiological mechanism by which CPAP treatment improves the prognosis of patients with CHD and OSA remains unclear. The purpose of this study was to clarify whether CPAP can improve arterial stiffness and inflammatory factor levels in CHD patients with OSA, and to further improve prognosis.

View Article and Find Full Text PDF

Complete expiratory central airway collapse at general anesthesia recovery: a case report.

J Int Med Res

January 2025

Department of Anesthesiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China.

Expiratory central airway collapse is a degenerative tracheobronchial disease that is often overlooked because of its nonspecific clinical features. A man was admitted for evaluation of tracheal nodules. Following bronchoscopic biopsy, a significant increase in airway pressure occurred during anesthesia recovery.

View Article and Find Full Text PDF

Chronic cough is a distressing and prevalent symptom in interstitial lung disease (ILD), significantly impairing quality of life (QoL) and contributing to disease progression, particularly in idiopathic pulmonary fibrosis (IPF). It is associated with physical discomfort, psychological distress, and social isolation and is often refractory to conventional therapies. The pathophysiology of cough in ILD is complex and multifactorial, involving neural hypersensitivity, structural lung changes, inflammatory processes, and comorbid conditions such as gastroesophageal reflux disease (GERD).

View Article and Find Full Text PDF

Asthma (a chronic inflammatory disease of the airways) is characterized by a variable course, response to treatment, and prognosis. Its incidence has increased significantly in recent decades. Unfortunately, modern lifestyle and environmental factors contribute to the further increase in the incidence of this disease.

View Article and Find Full Text PDF

Background: Double cycling with breath-stacking (DC/BS) during controlled mechanical ventilation is considered potentially injurious, reflecting a high respiratory drive. During partial ventilatory support, its occurrence might be attributable to physiological variability of breathing patterns, reflecting the response of the mode without carrying specific risks.

Methods: This secondary analysis of a crossover study evaluated DC/BS events in hypoxemic patients resuming spontaneous breathing in cross-over under neurally adjusted ventilatory assist (NAVA), proportional assist ventilation (PAV +), and pressure support ventilation (PSV).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!