A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simple and economical HandClench Relaxometer device for reliable and sensitive measurement of grip myotonia in myotonic dystrophy. | LitMetric

Grip myotonia and weakness are attractive treatment response biomarkers in clinical trials of myotonic dystrophy type 1 (DM1). There is a need to develop simple, patient-friendly and reproducible methods of quantifying grip myotonia in multisite trial settings. We designed a HandClench Relaxometer (HCR) that measures grip myotonia and strength. In contrast with the existing quantitative myometry (QMA) setup, the HCR is portable, economical, can be used with any laptop and generates automated command prompts. We demonstrate the feasibility and reliability of HCR device in twenty DM1 individuals and ten age-matched controls; patients returned for follow up within two months. The device showed excellent day to day reproducibility (ICC >0.80) in patients. The HCR device detected myotonia in milder muscle disease and measured longer myotonia duration than QMA indicating enhanced sensitivity for quantifying myotonia in DM1. The reaction time to the relax but not squeeze command was delayed and showed warm up similar to myotonia in DM1. HCR outcomes were correlated with key pinch strength, hand dexterity test, and fat replacement in the MRI of the long finger flexor muscles. Use of the HCR is warranted for grip myotonia and strength measurements in longitudinal observational and interventional studies of DM1.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.nmd.2022.02.005DOI Listing

Publication Analysis

Top Keywords

grip myotonia
20
myotonia
9
handclench relaxometer
8
myotonic dystrophy
8
myotonia strength
8
hcr device
8
myotonia dm1
8
hcr
6
grip
5
dm1
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!